An intensified ultra-high-speed optical emission spectroscopy system for hypersonic impulse test facilities

Abstract This paper provides a comprehensive investigation into creating a spectroscopy system capable of capturing quantitative data that are spatially, spectrally, and temporally resolved, at a minimum of 100 kHz frame rate using an ultra-high-speed camera, a high-speed image intensifier, and a spectrograph. The system was thoroughly tested in a controlled environment using a PhatLight green LED and a Labsphere CSTM-USS400-HI calibration lamp to determine its capabilities and limitations. The sensitivity at different wavelengths and how exposure time and intensifier gain settings affect the sensitivity of the system were evaluated. The system performed well with an exception of a drop in intensity when recording over long periods of time. Upon investigation, it was discovered that the intensifier cannot sustain a constant gain at higher counts for extended lengths of time. The gain drop in the intensifier is minimal for test times less than 200 $$\mu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> s, allowing the system to be operated on short-duration facilities. For test times of milliseconds, the gain drop must be accounted for either in data calibration or analysis. The system proved successful in capturing spectral data at a 100-kHz frame rate on the University of Queensland’s X2 free-piston driven expansion tube, when investigating contamination in the facility. The ultra-high-speed intensified optical emission spectroscopy system allowed for spectral data that were spatially, spectrally, and temporally resolved in a short-duration hypersonic impulse testing facility, giving a better understanding of interactions and phenomena occurring in radiating flow.

Authors

Institutions

Publication Details

Journal
Experiments in Fluids
Published
2025-03-05
DOI
https://doi.org/10.1007/s00348-025-03999-x
Primary Topic
Gas Dynamics and Kinetic Theory
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An intensified ultra-high-speed optical emission spectroscopy system for hypersonic impulse test facilities

Timothy J. McIntyre, Andreas Andrianatos, Carolyn Jacobs, Christopher M. James et al.
Experiments in Fluids
Gas Dynamics and Kinetic Theory
article

An intensified ultra-high-speed optical emission spectroscopy system for hypersonic impulse test facilities

Timothy J. McIntyre, Andreas Andrianatos, Carolyn Jacobs, Christopher M. James, Nathan Lu
article en

Abstract

Abstract This paper provides a comprehensive investigation into creating a spectroscopy system capable of capturing quantitative data that are spatially, spectrally, and temporally resolved, at a minimum of 100 kHz frame rate using an ultra-high-speed camera, a high-speed image intensifier, and a spectrograph. The system was thoroughly tested in a controlled environment using a PhatLight green LED and a Labsphere CSTM-USS400-HI calibration lamp to determine its capabilities and limitations. The sensitivity at different wavelengths and how exposure time and intensifier gain settings affect the sensitivity of the system were evaluated. The system performed well with an exception of a drop in intensity when recording over long periods of time. Upon investigation, it was discovered that the intensifier cannot sustain a constant gain at higher counts for extended lengths of time. The gain drop in the intensifier is minimal for test times less than 200 $$\mu$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mi>μ</mml:mi> </mml:math> s, allowing the system to be operated on short-duration facilities. For test times of milliseconds, the gain drop must be accounted for either in data calibration or analysis. The system proved successful in capturing spectral data at a 100-kHz frame rate on the University of Queensland’s X2 free-piston driven expansion tube, when investigating contamination in the facility. The ultra-high-speed intensified optical emission spectroscopy system allowed for spectral data that were spatially, spectrally, and temporally resolved in a short-duration hypersonic impulse testing facility, giving a better understanding of interactions and phenomena occurring in radiating flow.

Experiments in FluidsVol. 66(4)
The University of Queensland (AU)
University of Queensland
Openalex Percentile: Top 93%
Gas Dynamics and Kinetic Theory
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.