A Highly Efficient and Automated Magnetic Bead Extraction Method Overcomes the Matrix Effect in LC–MS/MS Analysis of Human Serum Steroid Hormones

Profiling of steroid hormones is incredibly valuable in clinical settings for diagnosing endocrine disorders. However, the presence of matrix effects and labor-intensive manual work in LC-MS/MS analysis has hindered its routine application. In the present study, a highly efficient and automated magnetic bead extraction method was developed to address matrix effects and quantitatively profile 15 steroid hormones in human serum. Octadecyl (C18) and <i>N</i>-vinylpyrrolidone divinylbenzene (HLB) modified magnetic beads were compared for enriching steroids from human serum. Following enrichment, the beads were separated using a magnetic field; the matrix was cleaned, and the steroid hormones were eluted from the beads for LC-MS/MS analysis. This entire process of enrichment, cleanup, and elution was conducted automatically, making it simple, fast, and cost-effective. The results indicated that steroid hormones could be selectively enriched from human serum in just 1 min using C18 magnetic beads. The absolute matrix effect, evaluated as the relative response between human serum matrix and methanol solution, ranged from 89.2% to 113.1% for low levels, from 82.3% to 112.0% for medium levels, and from 91.7% to 111.0% for high levels. The intrabatch coefficients of variation (CVs) and interbatch CVs were between 3.1% and 13.4% and between 3.0% and 13.7%, respectively. Recoveries were between 87.6% and 114.3% for low levels, 94.0% and 105.0% for medium levels, and 91.9% and 111.7% for high levels. The clinical application was demonstrated by profiling steroid hormones in 160 pregnant women at various gestational weeks. The results suggested that the automated magnetic bead extraction method for LC-MS/MS could effectively address matrix effects in profiling steroid hormones. To our knowledge, this is the first automated magnetic bead extraction method for LC-MS/MS profiling of steroid hormones in clinical practice.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2025-03-05
DOI
https://doi.org/10.1021/jasms.4c00338
Citations
4
Primary Topic
Hormonal and reproductive studies
Type
article
Field-Weighted Citation Impact
5.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Highly Efficient and Automated Magnetic Bead Extraction Method Overcomes the Matrix Effect in LC–MS/MS Analysis of Human Serum Steroid Hormones

Xiaojing Huang, Yufeng Xiong, Yingsong Wu, Xiaoyi Yi
4 citations
Journal of the American Society for Mass Spectrometry
Hormonal and reproductive studies
5.18
article

A Highly Efficient and Automated Magnetic Bead Extraction Method Overcomes the Matrix Effect in LC–MS/MS Analysis of Human Serum Steroid Hormones

Xiaojing Huang, Yufeng Xiong, Yingsong Wu, Xiaoyi Yi
article en
4 citations

Abstract

Profiling of steroid hormones is incredibly valuable in clinical settings for diagnosing endocrine disorders. However, the presence of matrix effects and labor-intensive manual work in LC-MS/MS analysis has hindered its routine application. In the present study, a highly efficient and automated magnetic bead extraction method was developed to address matrix effects and quantitatively profile 15 steroid hormones in human serum. Octadecyl (C18) and <i>N</i>-vinylpyrrolidone divinylbenzene (HLB) modified magnetic beads were compared for enriching steroids from human serum. Following enrichment, the beads were separated using a magnetic field; the matrix was cleaned, and the steroid hormones were eluted from the beads for LC-MS/MS analysis. This entire process of enrichment, cleanup, and elution was conducted automatically, making it simple, fast, and cost-effective. The results indicated that steroid hormones could be selectively enriched from human serum in just 1 min using C18 magnetic beads. The absolute matrix effect, evaluated as the relative response between human serum matrix and methanol solution, ranged from 89.2% to 113.1% for low levels, from 82.3% to 112.0% for medium levels, and from 91.7% to 111.0% for high levels. The intrabatch coefficients of variation (CVs) and interbatch CVs were between 3.1% and 13.4% and between 3.0% and 13.7%, respectively. Recoveries were between 87.6% and 114.3% for low levels, 94.0% and 105.0% for medium levels, and 91.9% and 111.7% for high levels. The clinical application was demonstrated by profiling steroid hormones in 160 pregnant women at various gestational weeks. The results suggested that the automated magnetic bead extraction method for LC-MS/MS could effectively address matrix effects in profiling steroid hormones. To our knowledge, this is the first automated magnetic bead extraction method for LC-MS/MS profiling of steroid hormones in clinical practice.

Journal of the American Society for Mass SpectrometryVol. 36(4)
Nanfang Hospital (CN), Southern Medical University (CN)
Zero hunger
Openalex Percentile: Top 5%
Hormonal and reproductive studies
5.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.