Visual Detection of Canine Monocytic Ehrlichiosis Using Polymerase Chain Reaction-Based Lateral Flow Biosensors

A conventional PCR (cPCR) remains an effective molecular technique for the diagnosis of canine monocytic ehrlichiosis. However, agarose gel electrophoresis requires additional time after thermal cycling. In the present study, we developed a PCR-based lateral flow biosensor (PCR-LFB) to detect <i>Ehrlichia canis</i> (<i>E. canis</i>). Lateral flow strips allow for the simple and rapid detection of PCR products and provide an alternative to gel electrophoresis. The sensitivity, specificity, and detection limit of PCR-LFB were compared to those of TaqMan probe-based real-time PCRs (qPCRs). The PCR-LFB was performed with 5' 6-FITC and biotin-labeled primers specific to <i>E. canis</i>, targeting the <i>dsb</i> gene. The detection limit of the PCR-LFB assay was 10<sup>-6</sup> for the target DNA sequence in a 10-fold dilution of the recombinant plasmid, which is 10 times lower than that of qPCR. Among the confirmed qPCR results in the 30 dog samples, false-positive results were not detected by the PCR-LFB. Compared to qPCR, the sensitivity and specificity of PCR-LFB were 63.6% (95% CI; 42.9-80.2%) and 100% (95% CI; 67.5-100%), respectively. The Kappa value of the PCR-LFB is in moderate agreement with the qPCR (κ = 0.483). Perfect agreement (κ = 1) was observed between cPCR and PCR-LFB. Lower cost and shorter time consumption were demonstrated using PCR-LFB.

Authors

Institutions

Publication Details

Journal
Animals
Published
2025-03-05
DOI
https://doi.org/10.3390/ani15050740
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Visual Detection of Canine Monocytic Ehrlichiosis Using Polymerase Chain Reaction-Based Lateral Flow Biosensors

Sarawan Kaewmongkol, Peeravit Sumpavong, Gunn Kaewmongkol
Animals
Biosensors and Analytical Detection
article

Visual Detection of Canine Monocytic Ehrlichiosis Using Polymerase Chain Reaction-Based Lateral Flow Biosensors

Sarawan Kaewmongkol, Peeravit Sumpavong, Gunn Kaewmongkol
article en

Abstract

A conventional PCR (cPCR) remains an effective molecular technique for the diagnosis of canine monocytic ehrlichiosis. However, agarose gel electrophoresis requires additional time after thermal cycling. In the present study, we developed a PCR-based lateral flow biosensor (PCR-LFB) to detect <i>Ehrlichia canis</i> (<i>E. canis</i>). Lateral flow strips allow for the simple and rapid detection of PCR products and provide an alternative to gel electrophoresis. The sensitivity, specificity, and detection limit of PCR-LFB were compared to those of TaqMan probe-based real-time PCRs (qPCRs). The PCR-LFB was performed with 5' 6-FITC and biotin-labeled primers specific to <i>E. canis</i>, targeting the <i>dsb</i> gene. The detection limit of the PCR-LFB assay was 10<sup>-6</sup> for the target DNA sequence in a 10-fold dilution of the recombinant plasmid, which is 10 times lower than that of qPCR. Among the confirmed qPCR results in the 30 dog samples, false-positive results were not detected by the PCR-LFB. Compared to qPCR, the sensitivity and specificity of PCR-LFB were 63.6% (95% CI; 42.9-80.2%) and 100% (95% CI; 67.5-100%), respectively. The Kappa value of the PCR-LFB is in moderate agreement with the qPCR (κ = 0.483). Perfect agreement (κ = 1) was observed between cPCR and PCR-LFB. Lower cost and shorter time consumption were demonstrated using PCR-LFB.

AnimalsVol. 15(5)
Kasetsart University (TH)
National Research Council of Thailand
Openalex Percentile: Top 96%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Visual Detection of Canine Monocytic Ehrlichiosis Using Polymerase Chain Reaction-Based Lateral Flow Biosensors — Sarawan Kaewmongkol, Peeravit Sumpavong, et al. · Animals (2025) | TGRS Research Map | TGRS