Inter-Software Reproducibility of Quantitative Values of Myocardial Blood Flow and Coronary Flow Reserve Acquired by [13N]NH3 MPI PET/CT and the Effect of Motion Correction Tools
<b>Background:</b> The choice of software package (SP) for image processing affects the reproducibility of myocardial blood flow (MBF) values in [<sup>13</sup>N]NH<sub>3</sub> PET/CT scans. However, the impact of motion correction (MC) tools-integrated software motion correction (ISMC) or data-driven motion correction (DDMC)-on the inter-software reproducibility of MBF has not been studied. This research aims to evaluate reproducibility among three commonly used SPs and the role of MC. <b>Methods:</b> Thirty-six PET/CT studies from patients without myocardial ischemia or infarction were processed using QPET, Corridor-4DM (4DM), and syngo.MBF (syngo). MBF and coronary flow reserve (CFR) values were obtained without motion correction (NMC) and with ISMC and DDMC. Intraclass correlation coefficients (ICC) and Bland-Altman (BA) plots were used to analyze agreement. <b>Results:</b> Good or excellent reproducibility (ICC ≥ 0.77) was found for rest-MBF values, regardless of the SPs or use of MC. In contrast, stress-MBF and CFR values presented mostly a moderate agreement when NMC was used. The RCA territory consistently had the lowest agreement in stress-MBF and CFR in the comparisons involving QPET. The use of MC, particularly DDMC, enhanced the reproducibility of most of the stress-MBF and CFR values by improving ICCs and reducing bias and limits of agreement (LoA) in BA analysis. <b>Conclusions:</b> MBF quantification agreement between SPs is strong for rest-MBF values but suboptimal for stress-MBF and CFR values. MC tools, especially DDMC, are recommended for improving reproducibility in stress-MBF assessments, although differences in SP reproducibility up to 0.77 mL/g/min in global stress-MBF and up to 0.88 in global CFR remain despite the use of MC.
Authors
- Sergiy V. Lazarenko
- Riemer H. J. A. Slart (ORCID: https://orcid.org/0000-0002-5565-1164)
- Remco J.J. Knol (ORCID: https://orcid.org/0000-0003-1089-2981)
- Oscar Isaac Mendoza-Ibáñez (ORCID: https://orcid.org/0000-0002-5834-3909)
- Tonantzin Samara Martínez-Lucio (ORCID: https://orcid.org/0000-0002-5386-9290)
- Erick Alexánderson (ORCID: https://orcid.org/0000-0001-9446-7581)
- Friso M. van der Zant
Institutions
- University Medical Center Groningen (NL)
- University of Groningen (NL)
- Northwest Hospital (US)
- Instituto Nacional de Cardiología (MX)
- University of Twente (NL)
Publication Details
- Journal
- Diagnostics
- Published
- 2025-03-04
- DOI
- https://doi.org/10.3390/diagnostics15050613
- Citations
- 1
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 1.36