Energy estimation methods for positron emission tomography detectors composed of multiple scintillators

The performance and image quality of positron emission tomography (PET) systems can be enhanced by strategically employing multiple different scintillators, particularly those with different decay times. Two cutting-edge PET detector technologies employing different scintillators with different decay times are the phoswich detector and the emerging metascintillator. In PET imaging, accurate and precise energy measurement is important for effectively rejecting scattered gamma-rays and estimating scatter distribution. However, traditional measures of light output, such as amplitude or integration values of photosensor output pulses, cannot accurately indicate the deposit energy of gamma-rays across multiple scintillators. To address these issues, this study explores two methods for energy estimation in PET detectors that employ multiple scintillators. The first method uses pseudo-inverse matrix generated from the unique pulse profile of each crystal, while the second employs an artificial neural network (ANN) to estimate the energy deposited in each crystal. The effectiveness of the proposed methods was experimentally evaluated using three heavy and dense inorganic scintillation crystals (BGO, LGSO, and GAGG) and three fast plastic scintillators (EJ200, EJ224, and EJ232). The energy estimation method employing ANNs consistently demonstrated superior accuracy across all crystal combinations when compared to the approach utilizing the pseudo-inverse matrix. In the pseudo-inverse matrix approach, there is a negligible difference in accuracy when applying integral-based energy labels as opposed to amplitude-based energy labels. On the other hand, in ANN approach, employing integral-based energy labels consistently outperforms the use of amplitude-based energy labels. This study contributes to the advancement of PET detector technology by proposing and evaluating two methods for estimating the energy in the detector using multiple scintillators. The ANN approach appears to be a promising solution for improving the accuracy of energy estimation, addressing challenges posed by mixed scintillation pulses.

Authors

Institutions

Publication Details

Journal
Biomedical Engineering Letters
Published
2025-03-04
DOI
https://doi.org/10.1007/s13534-025-00464-w
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy estimation methods for positron emission tomography detectors composed of multiple scintillators

Hyeong Seok Shim, Jae Sung Lee, Min Jeong Cho
Biomedical Engineering Letters
Medical Imaging Techniques and Applications
article

Energy estimation methods for positron emission tomography detectors composed of multiple scintillators

Hyeong Seok Shim, Jae Sung Lee, Min Jeong Cho
article en

Abstract

The performance and image quality of positron emission tomography (PET) systems can be enhanced by strategically employing multiple different scintillators, particularly those with different decay times. Two cutting-edge PET detector technologies employing different scintillators with different decay times are the phoswich detector and the emerging metascintillator. In PET imaging, accurate and precise energy measurement is important for effectively rejecting scattered gamma-rays and estimating scatter distribution. However, traditional measures of light output, such as amplitude or integration values of photosensor output pulses, cannot accurately indicate the deposit energy of gamma-rays across multiple scintillators. To address these issues, this study explores two methods for energy estimation in PET detectors that employ multiple scintillators. The first method uses pseudo-inverse matrix generated from the unique pulse profile of each crystal, while the second employs an artificial neural network (ANN) to estimate the energy deposited in each crystal. The effectiveness of the proposed methods was experimentally evaluated using three heavy and dense inorganic scintillation crystals (BGO, LGSO, and GAGG) and three fast plastic scintillators (EJ200, EJ224, and EJ232). The energy estimation method employing ANNs consistently demonstrated superior accuracy across all crystal combinations when compared to the approach utilizing the pseudo-inverse matrix. In the pseudo-inverse matrix approach, there is a negligible difference in accuracy when applying integral-based energy labels as opposed to amplitude-based energy labels. On the other hand, in ANN approach, employing integral-based energy labels consistently outperforms the use of amplitude-based energy labels. This study contributes to the advancement of PET detector technology by proposing and evaluating two methods for estimating the energy in the detector using multiple scintillators. The ANN approach appears to be a promising solution for improving the accuracy of energy estimation, addressing challenges posed by mixed scintillation pulses.

Biomedical Engineering LettersVol. 15(3)
Seoul National University (KR)
Seoul National University
Affordable and clean energy
Openalex Percentile: Top 94%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.