Electrochemical bienzymatic biosensor for pyruvate kinase activity evaluation and inhibitor screening

This study describes the development of a pyruvate kinase (PyK)-biosensor for the evaluation of PyK activity, as a diagnostic tool for early cancer screening and detection of kinase inhibitors used in cancer treatment, with the evaluation of the inhibition mechanism. The biosensor was constructed by co-immobilizing the enzymes PyK and pyruvate oxidase (PyOx) on Au film electrodes by crosslinking with glutaraldehyde (GA) and evaluated electrochemically by cyclic voltammetry (CV) and fixed potential amperometry (CA). First, the experimental conditions were optimized in terms of applied potential, enzyme ratio PyK:PyOx and enzyme substrate concentration: phosphoenolpyruvate (PEP) and adenosine diphosphate (ADP). The biosensor sensitivity towards PEP detection was 2.11 ± 0.08 μA mM<sup>-1</sup> cm<sup>-2</sup>, with very high reproducibility and repeatability, which made it suitable for inhibition studies of PyK inhibitor. The inhibition mechanism of shikonin was determined in relation to both PEP and ADP, with the calculation of IC<sub>50</sub> values and binding constants (K<sub>i</sub>). Detection of shikonin was possible at very low concentrations in the linear range of 0.1-4.0 pM. The electrochemical results were validated by UV-Vis spectrophotometry. The developed biosensor is a valuable tool for drug screening by enabling enzyme catalytic function examination with applicability to identify inhibitors, estimate their affinity, inhibition mechanism linked to their molecular mechanisms of action and evaluate selectivity, of great interest in both pharmaceutical and medical domains.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2025-03-04
DOI
https://doi.org/10.1016/j.talanta.2025.127886
Citations
2
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical bienzymatic biosensor for pyruvate kinase activity evaluation and inhibitor screening

Mădălina M. Bârsan, Ricardo J.B. Leote, Victor C. Diculescu, Caroline G. Sanz
2 citations
Talanta
Electrochemical sensors and biosensors
1.46
article

Electrochemical bienzymatic biosensor for pyruvate kinase activity evaluation and inhibitor screening

Mădălina M. Bârsan, Ricardo J.B. Leote, Victor C. Diculescu, Caroline G. Sanz
article en
2 citations

Abstract

This study describes the development of a pyruvate kinase (PyK)-biosensor for the evaluation of PyK activity, as a diagnostic tool for early cancer screening and detection of kinase inhibitors used in cancer treatment, with the evaluation of the inhibition mechanism. The biosensor was constructed by co-immobilizing the enzymes PyK and pyruvate oxidase (PyOx) on Au film electrodes by crosslinking with glutaraldehyde (GA) and evaluated electrochemically by cyclic voltammetry (CV) and fixed potential amperometry (CA). First, the experimental conditions were optimized in terms of applied potential, enzyme ratio PyK:PyOx and enzyme substrate concentration: phosphoenolpyruvate (PEP) and adenosine diphosphate (ADP). The biosensor sensitivity towards PEP detection was 2.11 ± 0.08 μA mM<sup>-1</sup> cm<sup>-2</sup>, with very high reproducibility and repeatability, which made it suitable for inhibition studies of PyK inhibitor. The inhibition mechanism of shikonin was determined in relation to both PEP and ADP, with the calculation of IC<sub>50</sub> values and binding constants (K<sub>i</sub>). Detection of shikonin was possible at very low concentrations in the linear range of 0.1-4.0 pM. The electrochemical results were validated by UV-Vis spectrophotometry. The developed biosensor is a valuable tool for drug screening by enabling enzyme catalytic function examination with applicability to identify inhibitors, estimate their affinity, inhibition mechanism linked to their molecular mechanisms of action and evaluate selectivity, of great interest in both pharmaceutical and medical domains.

TalantaVol. 291
National Institute of Materials Physics (RO)
Openalex Percentile: Top 19%
Electrochemical sensors and biosensors
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electrochemical bienzymatic biosensor for pyruvate kinase activity evaluation and inhibitor screening — Mădălina M. Bârsan, Ricardo J.B. Leote, et al. · Talanta (2025) | TGRS Research Map | TGRS