Effective boron recovery from real acidic stripping solution by chemical oxo-precipitation method

The effluent generated during the desorption of boron from an ion exchange column is a major economic and environmental challenge of the ion exchange boron removal method. The chemical oxo-precipitation method (COP) is a rapid and efficient approach for boron removal from solutions of high concentration at room temperature. Therefore, this method was tested for boron removal using a real stripping solution obtained from boron desorption with hydrochloric acid after ion-exchange flue gas desulfurization (FGD) wastewater treatment. The following parameters were studied: hydrogen peroxide and calcium ratio to boron, pH of the solution, order of unit actions, pretreatment with oxidant, and calcium compound influence. We found that the literature recommended pre-oxidation step was unnecessary, and our process was rapid and effective, providing 96.8% of boron recovery after 5 min at room temperature using the following conditions: H 2 O 2 /B=3:1, Ca/B=2:1, pH=10.5 set after addition of chemicals. Since boron removal depends on at least three parameters, our novel approach to obtain optimal conditions of boron removal involved the precipitation of perborates from real wastewater by applying the central composite design (CCD) as an experimental strategy. The optimum conditions determined from the CCD experiment were pH=9, H 2 O 2 /B=3.5, and Ca/B=3.5, resulting in 94% boron recovery (in real experiment). Our study proved that the COP method was suitable for boron recovery from real acidic stripping solution, making the ion-exchange method of boron removal fully complete, economical, and environmentally friendly. • COP method is suitable for boron recovery from real acidic stripping solution • The proposed COP process is very fast and effective • Response surface methodology helps find optimum parameters of boron precipitation • Recovery of boron from stripping solution after FGD wastewater pretreatment • Complement to boron ion exchange removal from real FGD wastewater

Authors

Institutions

Publication Details

Journal
Water Resources and Industry
Published
2025-03-04
DOI
https://doi.org/10.1016/j.wri.2025.100286
Citations
2
Primary Topic
Extraction and Separation Processes
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effective boron recovery from real acidic stripping solution by chemical oxo-precipitation method

Alicja Kazek‐Kęsik, Krzysztof Karoń, Sylwia Bajkacz, Agata Jakóbik‐Kolon et al.
2 citations
Water Resources and Industry
Extraction and Separation Processes
1.43
article

Effective boron recovery from real acidic stripping solution by chemical oxo-precipitation method

Alicja Kazek‐Kęsik, Krzysztof Karoń, Sylwia Bajkacz, Agata Jakóbik‐Kolon, Joanna Bok-Badura, Łukasz Kot
article en
2 citations

Abstract

The effluent generated during the desorption of boron from an ion exchange column is a major economic and environmental challenge of the ion exchange boron removal method. The chemical oxo-precipitation method (COP) is a rapid and efficient approach for boron removal from solutions of high concentration at room temperature. Therefore, this method was tested for boron removal using a real stripping solution obtained from boron desorption with hydrochloric acid after ion-exchange flue gas desulfurization (FGD) wastewater treatment. The following parameters were studied: hydrogen peroxide and calcium ratio to boron, pH of the solution, order of unit actions, pretreatment with oxidant, and calcium compound influence. We found that the literature recommended pre-oxidation step was unnecessary, and our process was rapid and effective, providing 96.8% of boron recovery after 5 min at room temperature using the following conditions: H 2 O 2 /B=3:1, Ca/B=2:1, pH=10.5 set after addition of chemicals. Since boron removal depends on at least three parameters, our novel approach to obtain optimal conditions of boron removal involved the precipitation of perborates from real wastewater by applying the central composite design (CCD) as an experimental strategy. The optimum conditions determined from the CCD experiment were pH=9, H 2 O 2 /B=3.5, and Ca/B=3.5, resulting in 94% boron recovery (in real experiment). Our study proved that the COP method was suitable for boron recovery from real acidic stripping solution, making the ion-exchange method of boron removal fully complete, economical, and environmentally friendly. • COP method is suitable for boron recovery from real acidic stripping solution • The proposed COP process is very fast and effective • Response surface methodology helps find optimum parameters of boron precipitation • Recovery of boron from stripping solution after FGD wastewater pretreatment • Complement to boron ion exchange removal from real FGD wastewater

Water Resources and IndustryVol. 33
Silesian University of Technology (PL), NPO Energomash (Russia) (RU)
Clean water and sanitation
Openalex Percentile: Top 22%
Extraction and Separation Processes
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.