A Fault Line Selection Method for Single pole-to-ground fault in Flexible DC Distribution Networks

When the high resistance ground fault occurs in the flexible DC distribution network, the fault characteristics are weak and easy to be affected by noise, which leads to the difficulty of grounding line selection. To address this problem, a grounding fault line selection method based on the Hamming distance correlation coefficient of two-terminal zero-mode current is proposed. Firstly, the zero-mode currents at both ends of the line are selected as fault data, then, the Hamming distance between the zero-mode currents at both ends of the line is used to judge the difference between the lines, finally, the Hamming distance correlation coefficient is constructed to judge the fault line. The method proposed in this paper was verified through MATLAB/Simulink simulations, demonstrating its robustness against factors such as transition resistance, noise interference, fault location, and communication delay. Compared to Pearson and Spearman correlation coefficients, using the Hamming distance correlation coefficient for fault line detection offers higher reliability.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/icips64173.2024.10900248
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fault Line Selection Method for Single pole-to-ground fault in Flexible DC Distribution Networks

Huifen Zhang, Rui Yu, Jinheng Zhao
HVDC Systems and Fault Protection
article

A Fault Line Selection Method for Single pole-to-ground fault in Flexible DC Distribution Networks

Huifen Zhang, Rui Yu, Jinheng Zhao
article en

Abstract

When the high resistance ground fault occurs in the flexible DC distribution network, the fault characteristics are weak and easy to be affected by noise, which leads to the difficulty of grounding line selection. To address this problem, a grounding fault line selection method based on the Hamming distance correlation coefficient of two-terminal zero-mode current is proposed. Firstly, the zero-mode currents at both ends of the line are selected as fault data, then, the Hamming distance between the zero-mode currents at both ends of the line is used to judge the difference between the lines, finally, the Hamming distance correlation coefficient is constructed to judge the fault line. The method proposed in this paper was verified through MATLAB/Simulink simulations, demonstrating its robustness against factors such as transition resistance, noise interference, fault location, and communication delay. Compared to Pearson and Spearman correlation coefficients, using the Hamming distance correlation coefficient for fault line detection offers higher reliability.

University of Jinan (CN)
Climate action
Openalex Percentile: Top 74%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Fault Line Selection Method for Single pole-to-ground fault in Flexible DC Distribution Networks — Huifen Zhang, Rui Yu, et al. · (2024) | TGRS Research Map | TGRS