Research on Fault Location Algorithm for Wind Farm Collecting Lines Based on Distributed Traveling Waves

In the hybrid line fault of the wind farm collection line, the complex traveling wave reflection phenomenon increases the difficulty of fault location. In order to solve this problem, this paper proposes to install a distributed traveling wave detection device on the line according to the structural and characteristic differences between the cable and the overhead line. The line is partitioned and the Pearson correlation coefficient is used to determine the fault interval. Through formula derivation, the influence of wave velocity on ranging accuracy is eliminated, and a fault location algorithm without wave velocity is derived by using the second component in SVD decomposition to calibrate the pulse modulus maximum of signal singularity. PSCAD simulation and MATLAB results show that compared with the traditional single-end and double-end ranging method, this method significantly improves the accuracy of fault location of wind farm collection line.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/icips64173.2024.10900271
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Fault Location Algorithm for Wind Farm Collecting Lines Based on Distributed Traveling Waves

Xinying Cui, Wanchao Liu, Xiaoyue Cao, Jiajia Sun et al.
Power Systems Fault Detection
article

Research on Fault Location Algorithm for Wind Farm Collecting Lines Based on Distributed Traveling Waves

Xinying Cui, Wanchao Liu, Xiaoyue Cao, Jiajia Sun, Chao‐Hui Yang, Wei Li
article en

Abstract

In the hybrid line fault of the wind farm collection line, the complex traveling wave reflection phenomenon increases the difficulty of fault location. In order to solve this problem, this paper proposes to install a distributed traveling wave detection device on the line according to the structural and characteristic differences between the cable and the overhead line. The line is partitioned and the Pearson correlation coefficient is used to determine the fault interval. Through formula derivation, the influence of wave velocity on ranging accuracy is eliminated, and a fault location algorithm without wave velocity is derived by using the second component in SVD decomposition to calibrate the pulse modulus maximum of signal singularity. PSCAD simulation and MATLAB results show that compared with the traditional single-end and double-end ranging method, this method significantly improves the accuracy of fault location of wind farm collection line.

Shandong University of Technology (CN), China Power Engineering Consulting Group (China) (CN), Shandong Electric Power Engineering Consulting Institute Corp (CN)
Affordable and clean energy
Openalex Percentile: Top 65%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.