Electric field analysis of transmission line insulator strings under different deterioration conditions

With the rapid development of the power industry, a large number of insulators have been used in the power transmission lines of the power system, and the existence of deteriorated insulators is a direct threat to the safe and stable operation of the power system. When the transmission line insulator string has deteriorated insulators, the insulation resistance and insulation strength will decrease, and flashover will easily occur, posing a serious threat to the security of the power grid. Therefore, it is necessary to analyze the electric field of insulators in different states and develop appropriate detection methods for deteriorated insulators. In this paper, firstly, the structure and deterioration principle of suspension porcelain insulator, as well as the spatial potential distribution of insulator string are analyzed, and the structural model of suspension porcelain insulator string is established by using the finite element simulation software ANSYS for simulation research. The spatial electric field distribution of 16 XWP-160 insulator strings is simulated. By changing the insulation resistance and relative permittivity of insulator piece to simulate the different states of insulator piece, the electric field distribution of insulator string in different states is calculated, and the electric field variation law of insulator string is further studied. The research shows that the degree of insulator deterioration (insulation resistance) and the number of deteriorated insulators have a great impact on the distribution of space electric field. The deeper the degree of deterioration, the greater the electric field distortion; The more the number of deteriorated insulators, the greater the electric field distortion. The change of electric field value of insulator under different conditions varies linearly with the degree of deterioration (insulation resistance).

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/icips64173.2024.10899973
Citations
2
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.23
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electric field analysis of transmission line insulator strings under different deterioration conditions

Huikun Pei, Manting Chen, Xi Chen, Zhiwen Fang et al.
2 citations
High voltage insulation and dielectric phenomena
0.23
article

Electric field analysis of transmission line insulator strings under different deterioration conditions

Huikun Pei, Manting Chen, Xi Chen, Zhiwen Fang, N. Zeng
article en
2 citations

Abstract

With the rapid development of the power industry, a large number of insulators have been used in the power transmission lines of the power system, and the existence of deteriorated insulators is a direct threat to the safe and stable operation of the power system. When the transmission line insulator string has deteriorated insulators, the insulation resistance and insulation strength will decrease, and flashover will easily occur, posing a serious threat to the security of the power grid. Therefore, it is necessary to analyze the electric field of insulators in different states and develop appropriate detection methods for deteriorated insulators. In this paper, firstly, the structure and deterioration principle of suspension porcelain insulator, as well as the spatial potential distribution of insulator string are analyzed, and the structural model of suspension porcelain insulator string is established by using the finite element simulation software ANSYS for simulation research. The spatial electric field distribution of 16 XWP-160 insulator strings is simulated. By changing the insulation resistance and relative permittivity of insulator piece to simulate the different states of insulator piece, the electric field distribution of insulator string in different states is calculated, and the electric field variation law of insulator string is further studied. The research shows that the degree of insulator deterioration (insulation resistance) and the number of deteriorated insulators have a great impact on the distribution of space electric field. The deeper the degree of deterioration, the greater the electric field distortion; The more the number of deteriorated insulators, the greater the electric field distortion. The change of electric field value of insulator under different conditions varies linearly with the degree of deterioration (insulation resistance).

Shenzhen Stock Exchange (CN)
Affordable and clean energy
Openalex Percentile: Top 49%
High voltage insulation and dielectric phenomena
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.