This work introduces a novel machine learning-based approach for monitoring of the hemoglobin concentration (HbConc) and oxygen saturation (SO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>) levels of blood samples. These two parameters are the key biomarkers for diagnosing anemia and hypoxia. Traditional methods are often invasive, uncomfortable and not fit for continuous patient management, while non-invasive options like pulse oximetry lack accuracy. We propose a support vector regression (SVR) model, which was trained on simulated photoacoustic (PA) signal dataset. At first fluence maps at 700 and 905 nm optical illuminations were generated for 1445 prototypes implementing a Monte-Carlo simulation framework accounting photon-transport in blood tissue. The prototypes resembled blood samples (hematocrit and SO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> were randomly varied from 31 to 50% and 61 to 97%, respectively). Then the k-Wave toolbox was utilized to simulate the PA signals, having 201 data points with 10 ns spacing, keeping signal to noise ratio fixed at 40 dB for each signal. In approach 1, the entire signal was considered as a feature and accordingly, SVR model was trained and tested. In approach 2, 24 features extracted from each signal were utilized for the same tasks. We found that the second approach can accurately estimate the blood HbConc and SO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> states (accuracies up to 75% and 64%, respectively). In future, we will increase the dataset incorporating greater variability of blood samples to overcome the issue of overfitting of data. Moreover, the performance of the SVR will be tested on experimental PA signals acquired from human blood samples. Our results suggest that the SVR method in combination with the PA technology has the potential to determine these blood parameters with acceptable accuracies and thus it can be applied at clinical and particularly, at resource-limited settings.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/cict64037.2024.10899584
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SVR Model Dealing with Photoacoustic Signals for Estimation of the Blood Hemoglobin Concentration and Oxygenation State

Ratan Kumar Saha, Aruna Pal, Subhradip Paul, Shashank Deep et al.
Photoacoustic and Ultrasonic Imaging
article

SVR Model Dealing with Photoacoustic Signals for Estimation of the Blood Hemoglobin Concentration and Oxygenation State

Ratan Kumar Saha, Aruna Pal, Subhradip Paul, Shashank Deep, Tapobrata Lahiri, K Niharika, Jai Moryani, Surendra Tholiya
article en

Abstract

This work introduces a novel machine learning-based approach for monitoring of the hemoglobin concentration (HbConc) and oxygen saturation (SO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>) levels of blood samples. These two parameters are the key biomarkers for diagnosing anemia and hypoxia. Traditional methods are often invasive, uncomfortable and not fit for continuous patient management, while non-invasive options like pulse oximetry lack accuracy. We propose a support vector regression (SVR) model, which was trained on simulated photoacoustic (PA) signal dataset. At first fluence maps at 700 and 905 nm optical illuminations were generated for 1445 prototypes implementing a Monte-Carlo simulation framework accounting photon-transport in blood tissue. The prototypes resembled blood samples (hematocrit and SO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> were randomly varied from 31 to 50% and 61 to 97%, respectively). Then the k-Wave toolbox was utilized to simulate the PA signals, having 201 data points with 10 ns spacing, keeping signal to noise ratio fixed at 40 dB for each signal. In approach 1, the entire signal was considered as a feature and accordingly, SVR model was trained and tested. In approach 2, 24 features extracted from each signal were utilized for the same tasks. We found that the second approach can accurately estimate the blood HbConc and SO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> states (accuracies up to 75% and 64%, respectively). In future, we will increase the dataset incorporating greater variability of blood samples to overcome the issue of overfitting of data. Moreover, the performance of the SVR will be tested on experimental PA signals acquired from human blood samples. Our results suggest that the SVR method in combination with the PA technology has the potential to determine these blood parameters with acceptable accuracies and thus it can be applied at clinical and particularly, at resource-limited settings.

Indian Institute of Information Technology Allahabad (IN)
Douglas Bomford Trust, Science and Engineering Research Board
Openalex Percentile: Top 75%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.