Identification of model parameter and measurement error in large-scale power grid base on graph attention network

The analysis of deviation between measured value and estimated value in power system state estimation mainly relies on manual experience, and there is a lack of an intelligent auxiliary tools for model parameter and measurement error identification. This article proposes an intelligent method to diagnose the problem of the model parameter and measurement near the deviation point of state estimation (the point where the measured value deviates greatly from the estimated value) base on graph attention network (GAT). The subgraph is built according to the local network topology near the deviation point. We divide graph nodes into four categories: normal nodes, topology error nodes, measurement error nodes, and parameter error nodes, and establish a node classification network for diagnosis of model parameter and measurement error. The GAT network is trained by the method of supervised learning based on the power system model maintenance experience and automatic error generation. With proposed automatic sample generation technology, we can generate millions of training samples. We test the GAT network on China state grid model with more than 60000 buses and 70000 branches and the result has sufficient accuracy.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/icips64173.2024.10900016
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identification of model parameter and measurement error in large-scale power grid base on graph attention network

Yonggang Jiao, Zhen Zhang, Feng Han, LI Sen et al.
Smart Grid and Power Systems
article

Identification of model parameter and measurement error in large-scale power grid base on graph attention network

Yonggang Jiao, Zhen Zhang, Feng Han, LI Sen, Zhang Yin
article en

Abstract

The analysis of deviation between measured value and estimated value in power system state estimation mainly relies on manual experience, and there is a lack of an intelligent auxiliary tools for model parameter and measurement error identification. This article proposes an intelligent method to diagnose the problem of the model parameter and measurement near the deviation point of state estimation (the point where the measured value deviates greatly from the estimated value) base on graph attention network (GAT). The subgraph is built according to the local network topology near the deviation point. We divide graph nodes into four categories: normal nodes, topology error nodes, measurement error nodes, and parameter error nodes, and establish a node classification network for diagnosis of model parameter and measurement error. The GAT network is trained by the method of supervised learning based on the power system model maintenance experience and automatic error generation. With proposed automatic sample generation technology, we can generate millions of training samples. We test the GAT network on China state grid model with more than 60000 buses and 70000 branches and the result has sufficient accuracy.

North China Electric Power University (CN), China Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 74%
Smart Grid and Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.