Intermittent Discharge Characteristic of GIS under Suspended Electrode Defects

Compared to traditional power system devices, gas-insulated switchgear offers advantages such as excellent operational stability, a relatively compact internal structure, and reduced space requirements, making it widely used in substations. However, decades of operational experience indicate that unavoidable insulation defects may arise during manufacturing, transportation, installation, maintenance, and operation. To address the frequent issues of missed and false reports in monitoring partial discharge insulation defects in GIS, intermittent discharge has been identified as the root cause. This is because the time intervals between intermittent discharges are significantly longer than those of stable discharges, causing traditional partial discharge detection systems to misinterpret intermittent discharge pulses as interference signals and overlook them. Therefore, this study focuses on the intermittent discharge of floating potential defects in GIS. The results indicate that, as pressurization time increases, the discharge quantity of floating electrode defects initially increases and then decreases over time. With higher temperature levels, the discharge quantity progressively increases. Additionally, as temperature levels rise, the time intervals between intermittent discharges become shorter, leading to a decrease in discharge intermittency

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/icips64173.2024.10900319
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intermittent Discharge Characteristic of GIS under Suspended Electrode Defects

Dibo Wang, Meizhen Dai, Chuansheng Luo, Longfei Cui et al.
High voltage insulation and dielectric phenomena
article

Intermittent Discharge Characteristic of GIS under Suspended Electrode Defects

Dibo Wang, Meizhen Dai, Chuansheng Luo, Longfei Cui, Ling‐Yi Kong, Weihong Yang, Yan Luo
article en

Abstract

Compared to traditional power system devices, gas-insulated switchgear offers advantages such as excellent operational stability, a relatively compact internal structure, and reduced space requirements, making it widely used in substations. However, decades of operational experience indicate that unavoidable insulation defects may arise during manufacturing, transportation, installation, maintenance, and operation. To address the frequent issues of missed and false reports in monitoring partial discharge insulation defects in GIS, intermittent discharge has been identified as the root cause. This is because the time intervals between intermittent discharges are significantly longer than those of stable discharges, causing traditional partial discharge detection systems to misinterpret intermittent discharge pulses as interference signals and overlook them. Therefore, this study focuses on the intermittent discharge of floating potential defects in GIS. The results indicate that, as pressurization time increases, the discharge quantity of floating electrode defects initially increases and then decreases over time. With higher temperature levels, the discharge quantity progressively increases. Additionally, as temperature levels rise, the time intervals between intermittent discharges become shorter, leading to a decrease in discharge intermittency

Guangxi Hydraulic Power Machinery Research Institute (CN)
Openalex Percentile: Top 83%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.