Analysis on Heating Causes of Composite Insulators in Online Operation

In recent years, composite insulators have frequently been heated during online operation. Since the cause and mechanism of the heating are unclear, massive trouble had been caused to the relevant department. This paper has conducted a withstand voltage temperature rise test on the heating composite insulator and found that after the composite insulator shed absorbs water, its high-voltage end will generate obvious heating under the action of the operating voltage. Through the dissection test, it is speculated that due to defects in the core rod-sheath interface of the composite insulator, local discharge occurs at the interface on the high-voltage end side, causing the composite insulator to heat up, and finally causing serious damage to the core rod. During the alternating current (AC) field exposure of silicone rubber, it has been observed that the AC field enhances the solution’s permeation through the silicone rubber. This phenomenon could potentially be linked to the recurrent thermal issues experienced by composite insulators in proximity to the grading ring at the high-voltage end.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/icips64173.2024.10900146
Primary Topic
Advanced Manufacturing and Logistics Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis on Heating Causes of Composite Insulators in Online Operation

Hao Shen, Hongjie Jiang, Liming Wang, Hui Liu et al.
2 links
Advanced Manufacturing and Logistics Optimization
article

Analysis on Heating Causes of Composite Insulators in Online Operation

Hao Shen, Hongjie Jiang, Liming Wang, Hui Liu, Senlin Liao, Hongwei Mei, Chao Zhou
article en

Abstract

In recent years, composite insulators have frequently been heated during online operation. Since the cause and mechanism of the heating are unclear, massive trouble had been caused to the relevant department. This paper has conducted a withstand voltage temperature rise test on the heating composite insulator and found that after the composite insulator shed absorbs water, its high-voltage end will generate obvious heating under the action of the operating voltage. Through the dissection test, it is speculated that due to defects in the core rod-sheath interface of the composite insulator, local discharge occurs at the interface on the high-voltage end side, causing the composite insulator to heat up, and finally causing serious damage to the core rod. During the alternating current (AC) field exposure of silicone rubber, it has been observed that the AC field enhances the solution’s permeation through the silicone rubber. This phenomenon could potentially be linked to the recurrent thermal issues experienced by composite insulators in proximity to the grading ring at the high-voltage end.

Tsinghua–Berkeley Shenzhen Institute (CN)
Science and Technology Project of State Grid
Affordable and clean energy
Openalex Percentile: Top 59%
Advanced Manufacturing and Logistics Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis on Heating Causes of Composite Insulators in Online Operation — Hao Shen, Hongjie Jiang, et al. · (2024) | TGRS Research Map | TGRS