Composite Voltage And Current Arc Suppression Method Based on Zero-Sequence Voltage Threshold

To ensure the reliability of distribution network under single-line-to-ground (SLG) fault, the active voltage arc suppression (AVAS) method is usually adopted to suppress the arcs. However, its performance is unfavorable as the line impedance is practically not neglectable, especially when the low-resistance SLG fault occurs. For improvement, the active current arc suppression (ACAS) method is used as a supplement to effectively eliminate this shortcoming. Therefore, this paper proposes a composite arc suppression method, which combines the AVAS and ACAS method to suppress arc. Firstly, the limitation of AVAS method is analyzed. It is found that the residual current after AVAS can be presented by post-fault zero-sequence voltage. Then, a zero-sequence voltage threshold is set to distinguish which type of method should be adopted. When the zero-sequence voltage less than the voltage threshold, the AVAS method is adopted. When the zero-sequence voltage is larger than the voltage threshold, the ACAS method is used. The simulation results show that the proposed method has good arc suppression performance under different fault locations.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/icips64173.2024.10899948
Citations
1
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Composite Voltage And Current Arc Suppression Method Based on Zero-Sequence Voltage Threshold

Jin Zou, Weijun Zhu, Da Wang, Weimin Liu et al.
1 citations
Electrical Contact Performance and Analysis
0.21
article

Composite Voltage And Current Arc Suppression Method Based on Zero-Sequence Voltage Threshold

Jin Zou, Weijun Zhu, Da Wang, Weimin Liu, Wen Wang, Mei-Shu Chen
article en
1 citations

Abstract

To ensure the reliability of distribution network under single-line-to-ground (SLG) fault, the active voltage arc suppression (AVAS) method is usually adopted to suppress the arcs. However, its performance is unfavorable as the line impedance is practically not neglectable, especially when the low-resistance SLG fault occurs. For improvement, the active current arc suppression (ACAS) method is used as a supplement to effectively eliminate this shortcoming. Therefore, this paper proposes a composite arc suppression method, which combines the AVAS and ACAS method to suppress arc. Firstly, the limitation of AVAS method is analyzed. It is found that the residual current after AVAS can be presented by post-fault zero-sequence voltage. Then, a zero-sequence voltage threshold is set to distinguish which type of method should be adopted. When the zero-sequence voltage less than the voltage threshold, the AVAS method is adopted. When the zero-sequence voltage is larger than the voltage threshold, the ACAS method is used. The simulation results show that the proposed method has good arc suppression performance under different fault locations.

Changsha University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 48%
Electrical Contact Performance and Analysis
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Composite Voltage And Current Arc Suppression Method Based on Zero-Sequence Voltage Threshold — Jin Zou, Weijun Zhu, et al. · (2024) | TGRS Research Map | TGRS