Fault Diagnosis Method for Voltage Transformers Based on Multi-modal Data Fusion and GoogLeNet

Voltage transformers are critical components in power systems, and their operational state directly impacts the safety and stability of the grid. Due to the potential occurrence of inter-turn short circuit faults during prolonged operation, fault diagnosis of voltage transformers has become a research focus to ensure reliable grid performance. This paper proposes a fault diagnosis method for voltage transformers based on multi-sensor data fusion and GoogLeNet. By collecting multi-modal signals such as voltage, current, and temperature, the method employs Continuous Wavelet Transform (CWT) to extract time-frequency features of the signals and utilizes the entropy weight method to weight and fuse the multi-modal features, thereby generating a comprehensive feature map that fully characterizes fault attributes. In constructing the diagnostic model, the pre-trained GoogLeNet deep neural network is fine-tuned to enhance classification performance on small-sample datasets. Experimental results show that the proposed method reliably diagnoses inter-turn short circuits at 25%, 50%, and 75% severity levels, achieving an average accuracy of 97.6%.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/icips64173.2024.10899989
Primary Topic
Advanced Decision-Making Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault Diagnosis Method for Voltage Transformers Based on Multi-modal Data Fusion and GoogLeNet

Yao Jun Guan, Yuanchen Fang, Wang Nanji, Zixiang Wang et al.
Advanced Decision-Making Techniques
article

Fault Diagnosis Method for Voltage Transformers Based on Multi-modal Data Fusion and GoogLeNet

Yao Jun Guan, Yuanchen Fang, Wang Nanji, Zixiang Wang, Jia Liu, Jie Liu, Di Jin, Shujia Liang
article en

Abstract

Voltage transformers are critical components in power systems, and their operational state directly impacts the safety and stability of the grid. Due to the potential occurrence of inter-turn short circuit faults during prolonged operation, fault diagnosis of voltage transformers has become a research focus to ensure reliable grid performance. This paper proposes a fault diagnosis method for voltage transformers based on multi-sensor data fusion and GoogLeNet. By collecting multi-modal signals such as voltage, current, and temperature, the method employs Continuous Wavelet Transform (CWT) to extract time-frequency features of the signals and utilizes the entropy weight method to weight and fuse the multi-modal features, thereby generating a comprehensive feature map that fully characterizes fault attributes. In constructing the diagnostic model, the pre-trained GoogLeNet deep neural network is fine-tuned to enhance classification performance on small-sample datasets. Experimental results show that the proposed method reliably diagnoses inter-turn short circuits at 25%, 50%, and 75% severity levels, achieving an average accuracy of 97.6%.

China Three Gorges University (CN), State Grid Corporation of China (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 56%
Advanced Decision-Making Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.