An Adaptive Reclosing Method Based on Active Detection by IIDG

The adaptive reclosing of the distribution network does not have the ability to identify the nature of faults, and may blindly reclose with permanent faults, causing secondary impact on the system and electrical equipment. Therefore, an adaptive reclosing method for distribution networks based on IIDG active detection is proposed. By actively injecting multi frequency detection signals through IIDG, the feeder side voltage phase characteristic differences under transient/permanent faults were analyzed, and the identification of fault nature was achieved. If it is a permanent fault, the recloser blocked, otherwise reclose it immediately. The proposed method does not require communication or additional equipment, making it easy to implement in engineering. The simulation results have verified the effectiveness of the proposed method.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/icips64173.2024.10900226
Primary Topic
Power Line Communications and Noise
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Adaptive Reclosing Method Based on Active Detection by IIDG

Yubo Yuan, Jinglei Deng, Shuai Liang, Liangzhong Yao et al.
Power Line Communications and Noise
article

An Adaptive Reclosing Method Based on Active Detection by IIDG

Yubo Yuan, Jinglei Deng, Shuai Liang, Liangzhong Yao, Shi Chen
article en

Abstract

The adaptive reclosing of the distribution network does not have the ability to identify the nature of faults, and may blindly reclose with permanent faults, causing secondary impact on the system and electrical equipment. Therefore, an adaptive reclosing method for distribution networks based on IIDG active detection is proposed. By actively injecting multi frequency detection signals through IIDG, the feeder side voltage phase characteristic differences under transient/permanent faults were analyzed, and the identification of fault nature was achieved. If it is a permanent fault, the recloser blocked, otherwise reclose it immediately. The proposed method does not require communication or additional equipment, making it easy to implement in engineering. The simulation results have verified the effectiveness of the proposed method.

Wuhan University (CN), Shanghai Electric (China) (CN)
Research and Development
Openalex Percentile: Top 74%
Power Line Communications and Noise
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Adaptive Reclosing Method Based on Active Detection by IIDG — Yubo Yuan, Jinglei Deng, et al. · (2024) | TGRS Research Map | TGRS