Research on Electromagnetic Interference Signal Characteristics and Suppression Methods for High Frequency Partial Discharge Monitoring in Renewable Energy Stations

As China's energy transformation advances, the proportion of renewable energy power generation in the power system continues to increase. 35 kV power cables are widely used as collector lines in renewable energy stations. High frequency (HF) partial discharge (PD) online monitoring is an important means to discover potential insulation defects in power cables and evaluate their operational status. Compared with traditional power stations, renewable energy stations use a large number of power electronic equipment, which can generate severe HF and high intensity pulse interference. These interferences are prone to submerging weak PD signals, posing new and severe challenges to high-frequency PD detection. Based on the engineering practice of Ulanqab Renewable Energy Station, this paper conducts actual measurement research on high-frequency electromagnetic interference signals in the station. According to the topological wiring of the station, the source and characteristics of the interference signals are studied through multi-point synchronous comparison testing. According to the time-frequency characteristics of the signal, a pulse extraction method based on OTSU and local energy threshold is proposed. Then, according to the extracted large number of pulses, a repetitive pulse interference separation method based on spectral clustering was proposed, which successfully separated several similar pulses from field data. On this basis, combined with stencil test, each pulse interference signal is identified and separated one by one, thus achieving the strategy of eliminating high-frequency and strong repetitive pulse interference signals. Verified with field data, the interference suppression rate reached 93.67%, proving the feasibility of this strategy.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Delivery
Published
2025-03-04
DOI
https://doi.org/10.1109/tpwrd.2025.3547345
Citations
3
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
3.64
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Electromagnetic Interference Signal Characteristics and Suppression Methods for High Frequency Partial Discharge Monitoring in Renewable Energy Stations

Bo Qi, Junkang Chen, Zhiguo Tang, Shusheng Zheng et al.
3 citations
IEEE Transactions on Power Delivery
Advanced Sensor and Control Systems
3.64
article

Research on Electromagnetic Interference Signal Characteristics and Suppression Methods for High Frequency Partial Discharge Monitoring in Renewable Energy Stations

Bo Qi, Junkang Chen, Zhiguo Tang, Shusheng Zheng, Xinfeng Tang, Ke Zhang, Wei Li
article en
3 citations

Abstract

As China's energy transformation advances, the proportion of renewable energy power generation in the power system continues to increase. 35 kV power cables are widely used as collector lines in renewable energy stations. High frequency (HF) partial discharge (PD) online monitoring is an important means to discover potential insulation defects in power cables and evaluate their operational status. Compared with traditional power stations, renewable energy stations use a large number of power electronic equipment, which can generate severe HF and high intensity pulse interference. These interferences are prone to submerging weak PD signals, posing new and severe challenges to high-frequency PD detection. Based on the engineering practice of Ulanqab Renewable Energy Station, this paper conducts actual measurement research on high-frequency electromagnetic interference signals in the station. According to the topological wiring of the station, the source and characteristics of the interference signals are studied through multi-point synchronous comparison testing. According to the time-frequency characteristics of the signal, a pulse extraction method based on OTSU and local energy threshold is proposed. Then, according to the extracted large number of pulses, a repetitive pulse interference separation method based on spectral clustering was proposed, which successfully separated several similar pulses from field data. On this basis, combined with stencil test, each pulse interference signal is identified and separated one by one, thus achieving the strategy of eliminating high-frequency and strong repetitive pulse interference signals. Verified with field data, the interference suppression rate reached 93.67%, proving the feasibility of this strategy.

IEEE Transactions on Power DeliveryVol. 40(3)
North China Electric Power University (CN), China Three Gorges Corporation (China) (CN), State Grid Corporation of China (China) (CN), Shanghai Electric (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 8%
Advanced Sensor and Control Systems
3.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.