Drift-Compensated Magnetic Biosensors Using Concurrent Dual-Frequency Oscillators

Magnetic biosensors that utilize magnetic nanoparticles (MNPs) as labels for biodetection assays have gained prominence in recent years due to their potential for use in rapid, accessible, and low-cost diagnostics devices. Resonance-shift-based magnetic biosensors are particularly suited for such applications, as they are readily implemented in standard CMOS processes, do not require external biasing or magnetic fields, and often do not require complex preparation chemistry. However, LC oscillator-based sensing cells suffer from drift induced by temperature fluctuations and other slow-varying noise sources, significantly degrading the signal-to-noise ratio (SNR) and impairing the achievable limit of detection. In this work, we propose a drift compensation approach utilizing a dual-frequency oscillator, operating concurrently at two widely spaced frequencies that track each other. The oscillator is designed such that the magnetic susceptibility of MNPs is large at the lower frequency but small and negative at the higher frequency. Thus, drift causes the oscillation frequencies to shift together, which can be canceled out, whereas the desired magnetic signal is encoded in the frequency difference. This enables simultaneous sensing and drift compensation, unlike previous approaches that utilize frequency switching. A proof-of-concept <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2 \times 2$ </tex-math></inline-formula> array spectrometer integrated circuit (IC) is presented, which achieves sub-ppm sensitivity and can be completely powered and controlled from a laptop Universal Serial Bus (USB) interface. Each sensing cell consumes as little as 3.1 mW and is tunable over a wide frequency range of 1.2–1.65 GHz/2.9–4 GHz. A single-step, wash-free immunoassay to detect streptavidin is performed, highlighting the viability of the magnetic spectrometer IC for in vitro diagnostic bioassays.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Solid-State Circuits
Published
2025-03-04
DOI
https://doi.org/10.1109/jssc.2025.3544256
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Drift-Compensated Magnetic Biosensors Using Concurrent Dual-Frequency Oscillators

Constantine Sideris, Jui‐Hung Sun
IEEE Journal of Solid-State Circuits
Magnetic Field Sensors Techniques
article

Drift-Compensated Magnetic Biosensors Using Concurrent Dual-Frequency Oscillators

Constantine Sideris, Jui‐Hung Sun
article en

Abstract

Magnetic biosensors that utilize magnetic nanoparticles (MNPs) as labels for biodetection assays have gained prominence in recent years due to their potential for use in rapid, accessible, and low-cost diagnostics devices. Resonance-shift-based magnetic biosensors are particularly suited for such applications, as they are readily implemented in standard CMOS processes, do not require external biasing or magnetic fields, and often do not require complex preparation chemistry. However, LC oscillator-based sensing cells suffer from drift induced by temperature fluctuations and other slow-varying noise sources, significantly degrading the signal-to-noise ratio (SNR) and impairing the achievable limit of detection. In this work, we propose a drift compensation approach utilizing a dual-frequency oscillator, operating concurrently at two widely spaced frequencies that track each other. The oscillator is designed such that the magnetic susceptibility of MNPs is large at the lower frequency but small and negative at the higher frequency. Thus, drift causes the oscillation frequencies to shift together, which can be canceled out, whereas the desired magnetic signal is encoded in the frequency difference. This enables simultaneous sensing and drift compensation, unlike previous approaches that utilize frequency switching. A proof-of-concept <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2 \times 2$ </tex-math></inline-formula> array spectrometer integrated circuit (IC) is presented, which achieves sub-ppm sensitivity and can be completely powered and controlled from a laptop Universal Serial Bus (USB) interface. Each sensing cell consumes as little as 3.1 mW and is tunable over a wide frequency range of 1.2–1.65 GHz/2.9–4 GHz. A single-step, wash-free immunoassay to detect streptavidin is performed, highlighting the viability of the magnetic spectrometer IC for in vitro diagnostic bioassays.

IEEE Journal of Solid-State CircuitsVol. 60(9)
University of Southern California (US)
Office of Naval Research
Affordable and clean energy
Openalex Percentile: Top 97%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Drift-Compensated Magnetic Biosensors Using Concurrent Dual-Frequency Oscillators — Constantine Sideris, Jui‐Hung Sun · IEEE Journal of Solid-State Circuits (2025) | TGRS Research Map | TGRS