Development of a High-Sensitivity Triple-Band Nano-Biosensor Utilizing Petahertz Metamaterials for Optimal Absorption in Early-Stage Leukemia Detection

This research focuses on designing a novel miniaturized biosensor for early-stage detection of leukemia. The proposed sensor operates in the low petahertz (PHz) range. The primary prerequisites for the development process include multiband operation, compact physical size, near-perfect absorption at resonant frequencies, and insensitivity to the angle of incidence. These features are crucial for ensuring high-performance operation in microwave imaging (MWI) and have been achieved through meticulous design of the absorber’s geometry and dimensions. The sensor incorporates a dipole and two rings made of gold or silver, implanted on a silicon dioxide (SiO2) dielectric substrate with a fully metallic backplane. The evolution of the biosensor’s topology is detailed, along with comprehensive simulation studies conducted using a commercial full-wave electromagnetic (EM) solver. The operating principles are explained through parametric studies, analysis of absorption and refraction characteristics, discussions of electric and magnetic fields, and surface current density distributions. The device’s suitability for blood cancer diagnostics is demonstrated through full-wave analysis of the MWI system, highlighting the sensor’s ability to discriminate between healthy and cancerous samples through noticeable frequency shifts in absorption responses. Extensive comparisons with the state-of-the-art biosensors reported in recent literature show that the proposed device significantly improves spectral properties and achieves remarkable spatial resolution due to its PHz range operation when compared to the benchmark.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-03-04
DOI
https://doi.org/10.1109/jsen.2025.3544761
Citations
16
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
12.90

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a High-Sensitivity Triple-Band Nano-Biosensor Utilizing Petahertz Metamaterials for Optimal Absorption in Early-Stage Leukemia Detection

Ali Farmani, Sunil Lavadiya, Sławomir Kozieł, Musa N. Hamza et al.
16 citations
IEEE Sensors Journal
Advanced biosensing and bioanalysis techniques
12.90
article

Development of a High-Sensitivity Triple-Band Nano-Biosensor Utilizing Petahertz Metamaterials for Optimal Absorption in Early-Stage Leukemia Detection

Ali Farmani, Sunil Lavadiya, Sławomir Kozieł, Musa N. Hamza, Iftikhar Ud Din, Syeda Iffat Naqvi, Bruno Sanches, Mohammad Tariqul Islam, Md. Shabiul Islam
article en
16 citations

Abstract

This research focuses on designing a novel miniaturized biosensor for early-stage detection of leukemia. The proposed sensor operates in the low petahertz (PHz) range. The primary prerequisites for the development process include multiband operation, compact physical size, near-perfect absorption at resonant frequencies, and insensitivity to the angle of incidence. These features are crucial for ensuring high-performance operation in microwave imaging (MWI) and have been achieved through meticulous design of the absorber’s geometry and dimensions. The sensor incorporates a dipole and two rings made of gold or silver, implanted on a silicon dioxide (SiO2) dielectric substrate with a fully metallic backplane. The evolution of the biosensor’s topology is detailed, along with comprehensive simulation studies conducted using a commercial full-wave electromagnetic (EM) solver. The operating principles are explained through parametric studies, analysis of absorption and refraction characteristics, discussions of electric and magnetic fields, and surface current density distributions. The device’s suitability for blood cancer diagnostics is demonstrated through full-wave analysis of the MWI system, highlighting the sensor’s ability to discriminate between healthy and cancerous samples through noticeable frequency shifts in absorption responses. Extensive comparisons with the state-of-the-art biosensors reported in recent literature show that the proposed device significantly improves spectral properties and achieves remarkable spatial resolution due to its PHz range operation when compared to the benchmark.

IEEE Sensors JournalVol. 25(8)
Reykjavík University (IS), Multimedia University (MY), University of Engineering and Technology Taxila (PK), University of Cyberjaya (MY), Lorestan University (IR), University of Raparin (IQ), Marwadi University (IN), National University of Malaysia (MY)
Narodowe Centrum Nauki
Openalex Percentile: Top 1%
Advanced biosensing and bioanalysis techniques
12.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.