A novel correction method and tissue simulation approach for system polarization mode dispersion in polarization-sensitive OCT

Polarization Sensitive Optical Coherence Tomography (PS-OCT) provides tissue specific contrast by assessing tissue birefringence and optic axis (OA) orientation. Fiber-based PS-OCT systems suffer from polarization mode dispersion (PMD) due to birefringence induced by the optical fibers. We present a novel numerical method for correcting for PMD. By combining Jones eigenvector analysis with rotational Stokes analysis we construct a wavelength dependent correction matrix. We validate this novel method by simulating PS-OCT measurements. The newly found correction method is able to remove wavelength dependent effects and corect for an overall remaining OA rotation out of the Q-U plane.

Authors

Institutions

Publication Details

Published
2025-03-04
DOI
https://doi.org/10.1117/12.3046220
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel correction method and tissue simulation approach for system polarization mode dispersion in polarization-sensitive OCT

Patrick González, Johannes F. de Boer, Tatiana Soldati, Mathilde Binnekamp
Optical Coherence Tomography Applications
article

A novel correction method and tissue simulation approach for system polarization mode dispersion in polarization-sensitive OCT

Patrick González, Johannes F. de Boer, Tatiana Soldati, Mathilde Binnekamp
article en

Abstract

Polarization Sensitive Optical Coherence Tomography (PS-OCT) provides tissue specific contrast by assessing tissue birefringence and optic axis (OA) orientation. Fiber-based PS-OCT systems suffer from polarization mode dispersion (PMD) due to birefringence induced by the optical fibers. We present a novel numerical method for correcting for PMD. By combining Jones eigenvector analysis with rotational Stokes analysis we construct a wavelength dependent correction matrix. We validate this novel method by simulating PS-OCT measurements. The newly found correction method is able to remove wavelength dependent effects and corect for an overall remaining OA rotation out of the Q-U plane.

Vrije Universiteit Amsterdam (NL)
Climate action
Openalex Percentile: Top 96%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.