Performance of CFS trusses self-drilling screws connections under extreme loads

Cold-Formed Steel (CFS) roof trusses often use self-drilling screws for efficient on-site assembly. Premature screw connection failures can significantly compromise truss integrity under static and dynamic loads. Connection failures included individual screw failures under shear, bearing damage of connected parts at screw interfaces, and screw/material separation. Additionally, screw tilting impacts behavior significantly. In this paper, an experimental study of sixteen self-drilling screwed connections used in typical CFS roof trusses was performed. Connections varied in screws count from 2 to 12, sheet thickness of 0.89 mm, 1.17 mm, and 1.45 mm, and the sheet order. Increasing the number of screws to six improved the peak capacity and stiffness of the connection by 60 % and 255 %, respectively. Moreover, additional screws beyond six had minimal effect on capacity and stiffness and reduced ductility. Reversing the sheet thickness decreased initial stiffness by 30 % and peak load by 15 %, but increased energy absorption. Additionally, energy absorption of the connections increased by 45 % when increasing the number of screws from two to six screws.

Authors

Institutions

Publication Details

Journal
Structures
Published
2025-03-04
DOI
https://doi.org/10.1016/j.istruc.2025.108592
Citations
2
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
1.91
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of CFS trusses self-drilling screws connections under extreme loads

Alaa El-Sisi, Hesham Elemam, Ahmed H. Elbelbisi, Mohamed Elsawi Mahmoud et al.
2 citations
Structures
Structural Load-Bearing Analysis
1.91
article

Performance of CFS trusses self-drilling screws connections under extreme loads

Alaa El-Sisi, Hesham Elemam, Ahmed H. Elbelbisi, Mohamed Elsawi Mahmoud, Hani Salim
article en
2 citations

Abstract

Cold-Formed Steel (CFS) roof trusses often use self-drilling screws for efficient on-site assembly. Premature screw connection failures can significantly compromise truss integrity under static and dynamic loads. Connection failures included individual screw failures under shear, bearing damage of connected parts at screw interfaces, and screw/material separation. Additionally, screw tilting impacts behavior significantly. In this paper, an experimental study of sixteen self-drilling screwed connections used in typical CFS roof trusses was performed. Connections varied in screws count from 2 to 12, sheet thickness of 0.89 mm, 1.17 mm, and 1.45 mm, and the sheet order. Increasing the number of screws to six improved the peak capacity and stiffness of the connection by 60 % and 255 %, respectively. Moreover, additional screws beyond six had minimal effect on capacity and stiffness and reduced ductility. Reversing the sheet thickness decreased initial stiffness by 30 % and peak load by 15 %, but increased energy absorption. Additionally, energy absorption of the connections increased by 45 % when increasing the number of screws from two to six screws.

StructuresVol. 74
Zagazig University (EG), Egyptian Russian University (EG), University of Missouri (US), Southern Illinois University Edwardsville (US)
Openalex Percentile: Top 17%
Structural Load-Bearing Analysis
1.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.