Accurate and precise 230Th/232Th isotope ratio measurement by multi-collector inductively coupled plasma mass spectrometry using a pre-cell mass filter for collision/reaction cell (MC-ICP-MS/MS)

In this paper we present the high-precision and accurate <sup>230</sup>Th/<sup>232</sup>Th isotope ratio measurement by a novel multi-collector inductively coupled plasma mass spectrometer with a pre-cell mass filter and a MS/MS collision/reaction cell (Neoma™ MC-ICP-MS/MS). No tailing correction is needed for the <sup>230</sup>Th signal, as the tailing of an adjacent high intensity peak (abundance sensitivity) is effectively reduced due to high extent of Ar-based ion removal before the electrostatic analyser/magnetic sector. The obtained abundance sensitivity at m-2 (i.e. at m/z = 230) is less than 0.9 ppb, the measured signal in the mass region of interest is comparable to the background. The repeated <sup>230</sup>Th/<sup>232</sup>Th measurements of IRMM-035 and IRMM-036 Th isotope ratio reference materials gave 11.3459 ± 0.0073 ppm (relative uncertainty of 0.064 %, k = 2) and 3.0564 ± 0.0052 ppm (relative uncertainty of 0.17 %, k = 2), respectively. The obtained results agree well with the recommended, consensus values (11.380 ± 0.096 ppm and 3.047 ± 0.024 ppm, respectively) and literature reported ratios, but with a much-improved uncertainty due to the elimination of the need for tailing correction and a high signal-to-noise ratio on the reduced background. The findings offer a new possibility in thorium isotope measurements as well as other high-precision isotope analysis in several geological, environmental, safeguards and nuclear forensic applications.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2025-03-04
DOI
https://doi.org/10.1016/j.talanta.2025.127896
Citations
4
Primary Topic
Isotope Analysis in Ecology
Type
article
Field-Weighted Citation Impact
6.87

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accurate and precise 230Th/232Th isotope ratio measurement by multi-collector inductively coupled plasma mass spectrometry using a pre-cell mass filter for collision/reaction cell (MC-ICP-MS/MS)

Zsolt Varga, K. Mayer, Maria Wallenius
4 citations
Talanta
Isotope Analysis in Ecology
6.87
article

Accurate and precise 230Th/232Th isotope ratio measurement by multi-collector inductively coupled plasma mass spectrometry using a pre-cell mass filter for collision/reaction cell (MC-ICP-MS/MS)

Zsolt Varga, K. Mayer, Maria Wallenius
article en
4 citations

Abstract

In this paper we present the high-precision and accurate <sup>230</sup>Th/<sup>232</sup>Th isotope ratio measurement by a novel multi-collector inductively coupled plasma mass spectrometer with a pre-cell mass filter and a MS/MS collision/reaction cell (Neoma™ MC-ICP-MS/MS). No tailing correction is needed for the <sup>230</sup>Th signal, as the tailing of an adjacent high intensity peak (abundance sensitivity) is effectively reduced due to high extent of Ar-based ion removal before the electrostatic analyser/magnetic sector. The obtained abundance sensitivity at m-2 (i.e. at m/z = 230) is less than 0.9 ppb, the measured signal in the mass region of interest is comparable to the background. The repeated <sup>230</sup>Th/<sup>232</sup>Th measurements of IRMM-035 and IRMM-036 Th isotope ratio reference materials gave 11.3459 ± 0.0073 ppm (relative uncertainty of 0.064 %, k = 2) and 3.0564 ± 0.0052 ppm (relative uncertainty of 0.17 %, k = 2), respectively. The obtained results agree well with the recommended, consensus values (11.380 ± 0.096 ppm and 3.047 ± 0.024 ppm, respectively) and literature reported ratios, but with a much-improved uncertainty due to the elimination of the need for tailing correction and a high signal-to-noise ratio on the reduced background. The findings offer a new possibility in thorium isotope measurements as well as other high-precision isotope analysis in several geological, environmental, safeguards and nuclear forensic applications.

TalantaVol. 292
Joint Research Centre (DE)
Joint Research Centre
Openalex Percentile: Top 4%
Isotope Analysis in Ecology
6.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accurate and precise 230Th/232Th isotope ratio measurement by multi-collector inductively coupled plasma mass spectrometry using a pre-cell mass filter for collision/reaction cell (MC-ICP-MS/MS) — Zsolt Varga, K. Mayer, et al. · Talanta (2025) | TGRS Research Map | TGRS