A radiation toxicity biosensing platform based on radioresistant bacteria modified with dr_0423

Radiation toxicity is important for evaluating potential health risks associated with radioactive substances or environmental radioactivity. Whole-cell biosensors can be applied to quantify radiation toxicity, yet it is technically challenging to identify a radiation-sensitive gene in a radioresistant strain and to maintain an ideal microenvironment for the promising radiation toxicity measurement. Herein, we report a microfluidic radiation toxicity whole-cell biosensing scheme based on a transgenic bacteria, membrane microfabrication, dielectrophoresis (DEP)-based cell trapping and amperometric detection. We have identified a radiation-responsive gene promoter ( dr_0423 ) unique to the radioresistant strain D. radiodurans , leading to the development of transgenic bacteria DRPZ423 . The dr_0423 promoter activates the expression of beta-galactosidase upon DNA damage from ionizing irradiation, which catalyzes the conversion of p -aminophenyl beta-D-galacto-pyranoside (PAPG) to p -aminophenol (PAP), and generates electrons for amperometric detection. Our biosensing scheme was validated using X-ray and alpha particles, showing promising results with a relative standard deviation of 2.78–6.38 % and a recovery rate exceeding 93.3 %. This biosensing platform offers a reliable method for measuring radiation toxicity, suitable for various applications such as environmental hazard assessment and beyond. • A sensitive DEP-based biosensor was developed for radiation toxicity detection. • A new transgenic bacteria DRPZ423 with radiation-responsive gene was reported. • Biomimetic design uses ultra-thin PDMS membrane for enhanced specificity. • Low RSD (2.78–6.38 %) and high recovery rate (>93.3 %) were achieved.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2025-03-04
DOI
https://doi.org/10.1016/j.snb.2025.137546
Citations
1
Primary Topic
bioluminescence and chemiluminescence research
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A radiation toxicity biosensing platform based on radioresistant bacteria modified with dr_0423

Shifeng Cheng, Zhongning Jiang, Siping Huang, Marcos Marcos et al.
1 citations
Sensors and Actuators B Chemical
bioluminescence and chemiluminescence research
0.81
article

A radiation toxicity biosensing platform based on radioresistant bacteria modified with dr_0423

Shifeng Cheng, Zhongning Jiang, Siping Huang, Marcos Marcos, Xin Cui, Raymond H. W. Lam, Chengpeng Yang, Yun Qu, Cia‐Hin Lau, Vincent Li, Kaiyuan Yu, Xin Yao
article en
1 citations

Abstract

Radiation toxicity is important for evaluating potential health risks associated with radioactive substances or environmental radioactivity. Whole-cell biosensors can be applied to quantify radiation toxicity, yet it is technically challenging to identify a radiation-sensitive gene in a radioresistant strain and to maintain an ideal microenvironment for the promising radiation toxicity measurement. Herein, we report a microfluidic radiation toxicity whole-cell biosensing scheme based on a transgenic bacteria, membrane microfabrication, dielectrophoresis (DEP)-based cell trapping and amperometric detection. We have identified a radiation-responsive gene promoter ( dr_0423 ) unique to the radioresistant strain D. radiodurans , leading to the development of transgenic bacteria DRPZ423 . The dr_0423 promoter activates the expression of beta-galactosidase upon DNA damage from ionizing irradiation, which catalyzes the conversion of p -aminophenyl beta-D-galacto-pyranoside (PAPG) to p -aminophenol (PAP), and generates electrons for amperometric detection. Our biosensing scheme was validated using X-ray and alpha particles, showing promising results with a relative standard deviation of 2.78–6.38 % and a recovery rate exceeding 93.3 %. This biosensing platform offers a reliable method for measuring radiation toxicity, suitable for various applications such as environmental hazard assessment and beyond. • A sensitive DEP-based biosensor was developed for radiation toxicity detection. • A new transgenic bacteria DRPZ423 with radiation-responsive gene was reported. • Biomimetic design uses ultra-thin PDMS membrane for enhanced specificity. • Low RSD (2.78–6.38 %) and high recovery rate (>93.3 %) were achieved.

Sensors and Actuators B ChemicalVol. 433
Jinan University (CN), City University of Hong Kong (HK), Nanyang Technological University (SG), City University of Hong Kong, Shenzhen Research Institute (CN)
Research Grants Council, University Grants Committee
Openalex Percentile: Top 30%
bioluminescence and chemiluminescence research
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.