Spent fuel pool boil-off experiments with high power and high time resolution

• Experiments conducted for high rod power boil-off conditions. • Correlation between collapsed and mixture level position deduced from experiments. • Radial and axial temperature profiles in rod bundle during boil-off investigated. • Water eruption sources and effects analyzed. • Peak temperature of 800 °C reached in ultimate boil-off scenarios. The occurrence of spent fuel pool (SFP) accidents, in which the water level decreases below the top of the fuel assemblies (FA), may arise due to the loss of active pool cooling or pool leakage. In such scenarios, the ALADIN test facility of the TUD Dresden University of Technology is utilized to simulate a comprehensive boiling water reactor (BWR) FA in a 1:1 scale. This report supplements the existing data base with rod powers between 100 W and 350 W. Boil-off experiments will be analyzed in detail in relation to axial and radial temperature profiles as a function of time and heater power up to a maximum temperature of approximately 800 °C. Additionally, temperature excursion mitigating measures such as spray-cooling and flooding will be discussed.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Design
Published
2025-03-04
DOI
https://doi.org/10.1016/j.nucengdes.2025.113958
Primary Topic
Nuclear reactor physics and engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spent fuel pool boil-off experiments with high power and high time resolution

О. Е. Степанов, Christoph Schuster
Nuclear Engineering and Design
Nuclear reactor physics and engineering
article

Spent fuel pool boil-off experiments with high power and high time resolution

О. Е. Степанов, Christoph Schuster
article en

Abstract

• Experiments conducted for high rod power boil-off conditions. • Correlation between collapsed and mixture level position deduced from experiments. • Radial and axial temperature profiles in rod bundle during boil-off investigated. • Water eruption sources and effects analyzed. • Peak temperature of 800 °C reached in ultimate boil-off scenarios. The occurrence of spent fuel pool (SFP) accidents, in which the water level decreases below the top of the fuel assemblies (FA), may arise due to the loss of active pool cooling or pool leakage. In such scenarios, the ALADIN test facility of the TUD Dresden University of Technology is utilized to simulate a comprehensive boiling water reactor (BWR) FA in a 1:1 scale. This report supplements the existing data base with rod powers between 100 W and 350 W. Boil-off experiments will be analyzed in detail in relation to axial and radial temperature profiles as a function of time and heater power up to a maximum temperature of approximately 800 °C. Additionally, temperature excursion mitigating measures such as spray-cooling and flooding will be discussed.

Nuclear Engineering and DesignVol. 435
Gidropribor (RU), Technische Universität Dresden (DE)
Affordable and clean energy
Openalex Percentile: Top 95%
Nuclear reactor physics and engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.