Rapid quantification and PK-PD modeling of rocuronium bromide in beagles using portable mass spectrometer

Monitoring rocuronium bromide (Rocur) concentrations is crucial for assessing muscle relaxation in clinical anesthesia. However, no suitable instruments are currently available. This study explores the application of a portable mass spectrometer (MS) for the rapid detection of Rocur concentrations in whole blood from beagles, aiming to support the development of individualized pharmacokinetic-pharmacodynamic (PK-PD) models. Four beagles (1-1.5 years old, 8-12 kg) received a single intravenous dose of Rocur (3 ED₅₀, 0.748 mg/kg). Neuromuscular monitoring was conducted using the train of four (TOF) ratio. Blood samples (0.1 mL) were collected at predetermined intervals and during recovery, with TOF ratios recorded at corresponding time points. Rocur concentrations in whole blood (C<sub>b-Rocur</sub>) were quantified using both the Cell portable MS and high-performance liquid chromatography with mass spectrometry (HPLC-MS) for consistency assessment. Additionally, a PK-PD model was developed based on C<sub>b-Rocur</sub> measurements obtained from the Cell portable MS. A strong linear relationship was observed for Cell portable MS measurements within the range of 50-10,000 ng/mL (<i>y</i> = 1108.32 * <i>x</i> + 14873.99, <i>R</i> <sup>2</sup> = 0.993), with a limit of quantification (LOQ) of 50 ng/mL and a limit of detection (LOD) of 10 ng/mL. A strong linear correlation was found between the two techniques (<i>y</i> = 1.07 * <i>x</i> + 30.08, <i>p</i> < 0.0001, <i>R</i> <sup>2</sup> = 0.8948), with a relative standard deviation <15% for all concentrations. The C<sub>max</sub> values were 4.52 ± 1.16 μg/mL (Cell portable MS) and 4.89 ± 0.52 μg/mL (HPLC-MS), respectively. As C<sub>b-Rocur</sub> decreased, the TOF ratio gradually recovered, with an IC<sub>50</sub> of 0.25 ± 0.05 μg/mL. This study successfully applied the Cell portable MS for rapid quantitative Rocur analysis in whole blood, demonstrating high consistency with HPLC-MS. The findings also revealed the good correlation between the PK-PD properties of Rocur and TOF effects.

Authors

Institutions

Publication Details

Journal
Frontiers in Veterinary Science
Published
2025-03-04
DOI
https://doi.org/10.3389/fvets.2025.1543086
Citations
3
Primary Topic
Anesthesia and Sedative Agents
Type
article
Field-Weighted Citation Impact
6.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid quantification and PK-PD modeling of rocuronium bromide in beagles using portable mass spectrometer

Deying Gong, Wensheng Zhang, Xiaoxiao Li, Xing Liu et al.
3 citations
Frontiers in Veterinary Science
Anesthesia and Sedative Agents
6.57
article

Rapid quantification and PK-PD modeling of rocuronium bromide in beagles using portable mass spectrometer

Deying Gong, Wensheng Zhang, Xiaoxiao Li, Xing Liu, Pan Chang
article en
3 citations

Abstract

Monitoring rocuronium bromide (Rocur) concentrations is crucial for assessing muscle relaxation in clinical anesthesia. However, no suitable instruments are currently available. This study explores the application of a portable mass spectrometer (MS) for the rapid detection of Rocur concentrations in whole blood from beagles, aiming to support the development of individualized pharmacokinetic-pharmacodynamic (PK-PD) models. Four beagles (1-1.5 years old, 8-12 kg) received a single intravenous dose of Rocur (3 ED₅₀, 0.748 mg/kg). Neuromuscular monitoring was conducted using the train of four (TOF) ratio. Blood samples (0.1 mL) were collected at predetermined intervals and during recovery, with TOF ratios recorded at corresponding time points. Rocur concentrations in whole blood (C<sub>b-Rocur</sub>) were quantified using both the Cell portable MS and high-performance liquid chromatography with mass spectrometry (HPLC-MS) for consistency assessment. Additionally, a PK-PD model was developed based on C<sub>b-Rocur</sub> measurements obtained from the Cell portable MS. A strong linear relationship was observed for Cell portable MS measurements within the range of 50-10,000 ng/mL (<i>y</i> = 1108.32 * <i>x</i> + 14873.99, <i>R</i> <sup>2</sup> = 0.993), with a limit of quantification (LOQ) of 50 ng/mL and a limit of detection (LOD) of 10 ng/mL. A strong linear correlation was found between the two techniques (<i>y</i> = 1.07 * <i>x</i> + 30.08, <i>p</i> < 0.0001, <i>R</i> <sup>2</sup> = 0.8948), with a relative standard deviation <15% for all concentrations. The C<sub>max</sub> values were 4.52 ± 1.16 μg/mL (Cell portable MS) and 4.89 ± 0.52 μg/mL (HPLC-MS), respectively. As C<sub>b-Rocur</sub> decreased, the TOF ratio gradually recovered, with an IC<sub>50</sub> of 0.25 ± 0.05 μg/mL. This study successfully applied the Cell portable MS for rapid quantitative Rocur analysis in whole blood, demonstrating high consistency with HPLC-MS. The findings also revealed the good correlation between the PK-PD properties of Rocur and TOF effects.

Frontiers in Veterinary ScienceVol. 12
Sichuan University (CN), West China Hospital of Sichuan University (CN)
Clean water and sanitation
Openalex Percentile: Top 5%
Anesthesia and Sedative Agents
6.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.