Certification of Buildings and Measures of Energy Efficiency Class Improvement

Nowadays, the problems of energy efficiency and energy saving are found in different spheres of construction. Various energy-efficient technologies are used to reduce energy consumption. The certification process is carried out at different stages: design, construction and reconstruction, which is leading to improvement of energy efficiency of the building, etc. The article covered the European standards that determine the coefficient of seasonal use of thermal energy (E), as well as the current energy efficiency classes of the Republic of Armenia. Both the EU and the Republic of Armenia have tightened requirements for enclosing structures. In Armenia, the thermal characteristics of enclosing structures can be improved by 15% to 41% depending on the degree-day value of the heating period. The value of the specific characteristic of thermal energy depends on climatic conditions, space-planning solutions, orientation of the building, etc. The standardized value of this characteristic for heating and ventilation varies from 0.414 to 0.336 W/m<sup>3</sup>°C depending on the area of the heated building and its number of storeys. And for a residential building with an area of 1000 m<sup>2</sup> and more, the non-standardized value does not depend on the number of storeys of the building. Classes of energy efficiency of buildings are determined by the value of the deviation of the calculated value of the specific characteristic of the consumption of thermal energy for heating and ventilation of the building from the standardized one. For determining the class of energy efficiency, the article considers a one-story residential building without thermal insulation and with thermal insulation of enclosing structures. To increase the energy efficiency class of a building from D to C, it is necessary to improve the thermal characteristics of the enclosing structures, i.e. reduce heat loss of buildings by 30% or more.

Authors

Institutions

Publication Details

Journal
International Journal of Architecture Arts and Applications
Published
2025-02-27
DOI
https://doi.org/10.11648/j.ijaaa.20251101.15
Primary Topic
Construction Management and Sustainability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Certification of Buildings and Measures of Energy Efficiency Class Improvement

L. Martirosyan, Naira Egnatosyan, Siranush Egnatosyan, Aleksey Rudomyotkin
International Journal of Architecture Arts and Applications
Construction Management and Sustainability
article

Certification of Buildings and Measures of Energy Efficiency Class Improvement

L. Martirosyan, Naira Egnatosyan, Siranush Egnatosyan, Aleksey Rudomyotkin
article en

Abstract

Nowadays, the problems of energy efficiency and energy saving are found in different spheres of construction. Various energy-efficient technologies are used to reduce energy consumption. The certification process is carried out at different stages: design, construction and reconstruction, which is leading to improvement of energy efficiency of the building, etc. The article covered the European standards that determine the coefficient of seasonal use of thermal energy (E), as well as the current energy efficiency classes of the Republic of Armenia. Both the EU and the Republic of Armenia have tightened requirements for enclosing structures. In Armenia, the thermal characteristics of enclosing structures can be improved by 15% to 41% depending on the degree-day value of the heating period. The value of the specific characteristic of thermal energy depends on climatic conditions, space-planning solutions, orientation of the building, etc. The standardized value of this characteristic for heating and ventilation varies from 0.414 to 0.336 W/m<sup>3</sup>°C depending on the area of the heated building and its number of storeys. And for a residential building with an area of 1000 m<sup>2</sup> and more, the non-standardized value does not depend on the number of storeys of the building. Classes of energy efficiency of buildings are determined by the value of the deviation of the calculated value of the specific characteristic of the consumption of thermal energy for heating and ventilation of the building from the standardized one. For determining the class of energy efficiency, the article considers a one-story residential building without thermal insulation and with thermal insulation of enclosing structures. To increase the energy efficiency class of a building from D to C, it is necessary to improve the thermal characteristics of the enclosing structures, i.e. reduce heat loss of buildings by 30% or more.

International Journal of Architecture Arts and ApplicationsVol. 11(1)
National University of Architecture and Construction of Armenia (AM), Institute of Geological Sciences (AM), National Academy of Sciences of Armenia (AM)
Affordable and clean energy
Openalex Percentile: Top 96%
Construction Management and Sustainability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.