Study of the Influence of Limited Volume on the Pulsation of a Vapor-Gas Cavity during a High-Voltage Electrical Explosion in a Liquid

The influence of a limited volume on the hydrodynamic postdischarge processes during a high-voltage electric explosion (HVEE) and an explosion of a thin initiating conductor (ETIC) in a liquid is estimated, and the dynamics of a vapor-gas cavity (VGC) under those conditions is studied. Experimental studies have shown the advantage of the HVEE in comparison with the ETIC in terms of the energy contributed into the VGC expressed in an increase of the period of the VGC pulsation up to 55%. With the ETIC in a limited volume of the discharge chamber, the period of pulsation of the VGC decreases up to 7.5 times compared to the ETIC in an unlimited space under the same initial conditions. A method for calculating the quasi-static pressure during an electric explosion in a limited volume with limited geometric parameters was proposed. The correlation between the calculated quasi-static pressure and the amplitude of the generated first compression wave is mentioned.

Authors

Institutions

Publication Details

Journal
Surface Engineering and Applied Electrochemistry
Published
2024-12-01
DOI
https://doi.org/10.3103/s1068375524700376
Primary Topic
Combustion and Detonation Processes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of the Influence of Limited Volume on the Pulsation of a Vapor-Gas Cavity during a High-Voltage Electrical Explosion in a Liquid

O. V. Khvoshchan, T. D. Denisyuk, A. P. Smirnov
Surface Engineering and Applied Electrochemistry
Combustion and Detonation Processes
article

Study of the Influence of Limited Volume on the Pulsation of a Vapor-Gas Cavity during a High-Voltage Electrical Explosion in a Liquid

O. V. Khvoshchan, T. D. Denisyuk, A. P. Smirnov
article en

Abstract

The influence of a limited volume on the hydrodynamic postdischarge processes during a high-voltage electric explosion (HVEE) and an explosion of a thin initiating conductor (ETIC) in a liquid is estimated, and the dynamics of a vapor-gas cavity (VGC) under those conditions is studied. Experimental studies have shown the advantage of the HVEE in comparison with the ETIC in terms of the energy contributed into the VGC expressed in an increase of the period of the VGC pulsation up to 55%. With the ETIC in a limited volume of the discharge chamber, the period of pulsation of the VGC decreases up to 7.5 times compared to the ETIC in an unlimited space under the same initial conditions. A method for calculating the quasi-static pressure during an electric explosion in a limited volume with limited geometric parameters was proposed. The correlation between the calculated quasi-static pressure and the amplitude of the generated first compression wave is mentioned.

Surface Engineering and Applied ElectrochemistryVol. 60(6)
National Academy of Sciences of Ukraine (UA)
Openalex Percentile: Top 54%
Combustion and Detonation Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.