Nonenzymatic Electrochemical Sensor Device for On-Site Nitrate Determination Using Copper Anchored Magnetite Nanocomposites

Elevated nitrate (NO<sub>3</sub><sup>-</sup>) levels in potable water due to anthropogenic and geogenic activities pose a significant environmental threat. Herein, we report a highly efficient electrochemical sensor device for NO<sub>3</sub><sup>-</sup> detection using a copper-anchored magnetite (Cu@Fe<sub>3</sub>O<sub>4</sub>) nanocomposite. The electrochemical performance of the NO<sub>3</sub><sup>-</sup> sensor was highly durable and reliable on a glassy carbon electrode (GCE) and as a proof of concept, it has been translated to thermal vapor deposited gold electrodes (Au electrodes) chip integrated with a hand-held portable potentiostat connected to a smartphone with read out capabilities for onsite real field application. The Cu@Fe<sub>3</sub>O<sub>4</sub> nanocomposite was characterized using X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), high-resolution transmission electron microscopy (HRTEM) mapping, Raman spectroscopy, and X-ray photoelectron spectroscopy (XPS) to confirm phase purity and successful synthesis. The sensor exhibited high selectivity for NO<sub>3</sub><sup>-</sup> (<i>P</i> ≤ 0.05), stability up to 21 days with a minimal 1.2% signal decrease, and a linear detection range of 10-1000 μM, with a detection limit of 1.35 μM and sensitivity of 0.0342 μA/μM. It also showed reproducibility of a relative standard deviation (RSD 1.33%) and successfully detected NO<sub>3</sub><sup>-</sup> in real water samples. This robust sensor provides an effective tool for real-time environmental assessment of NO<sub>3</sub><sup>-</sup>, aiding public health protection.

Authors

Institutions

Publication Details

Journal
Langmuir
Published
2025-03-04
DOI
https://doi.org/10.1021/acs.langmuir.4c04903
Citations
8
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
5.89

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nonenzymatic Electrochemical Sensor Device for On-Site Nitrate Determination Using Copper Anchored Magnetite Nanocomposites

Mukti Mandal, Bimalendu Mukherjee, G. Dutta, Priyanka Mukherjee
8 citations
Langmuir
Analytical Chemistry and Sensors
5.89
article

Nonenzymatic Electrochemical Sensor Device for On-Site Nitrate Determination Using Copper Anchored Magnetite Nanocomposites

Mukti Mandal, Bimalendu Mukherjee, G. Dutta, Priyanka Mukherjee
article en
8 citations

Abstract

Elevated nitrate (NO<sub>3</sub><sup>-</sup>) levels in potable water due to anthropogenic and geogenic activities pose a significant environmental threat. Herein, we report a highly efficient electrochemical sensor device for NO<sub>3</sub><sup>-</sup> detection using a copper-anchored magnetite (Cu@Fe<sub>3</sub>O<sub>4</sub>) nanocomposite. The electrochemical performance of the NO<sub>3</sub><sup>-</sup> sensor was highly durable and reliable on a glassy carbon electrode (GCE) and as a proof of concept, it has been translated to thermal vapor deposited gold electrodes (Au electrodes) chip integrated with a hand-held portable potentiostat connected to a smartphone with read out capabilities for onsite real field application. The Cu@Fe<sub>3</sub>O<sub>4</sub> nanocomposite was characterized using X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), high-resolution transmission electron microscopy (HRTEM) mapping, Raman spectroscopy, and X-ray photoelectron spectroscopy (XPS) to confirm phase purity and successful synthesis. The sensor exhibited high selectivity for NO<sub>3</sub><sup>-</sup> (<i>P</i> ≤ 0.05), stability up to 21 days with a minimal 1.2% signal decrease, and a linear detection range of 10-1000 μM, with a detection limit of 1.35 μM and sensitivity of 0.0342 μA/μM. It also showed reproducibility of a relative standard deviation (RSD 1.33%) and successfully detected NO<sub>3</sub><sup>-</sup> in real water samples. This robust sensor provides an effective tool for real-time environmental assessment of NO<sub>3</sub><sup>-</sup>, aiding public health protection.

LangmuirVol. 41(10)
Indian Institute of Technology Kharagpur (IN), Biosensor (Italy) (IT)
Ministry of Housing and Urban Affairs
Openalex Percentile: Top 3%
Analytical Chemistry and Sensors
5.89
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.