A Multicenter Feasibility and Safety Study of a Novel Hybrid IVUS-OCT Imaging System

Currently, precise stent manipulation and placement in percutaneous coronary intervention remain compromised. Intravascular imaging techniques are often limited by either spatial resolution or depth of penetration. A hybrid intravascular ultrasound (IVUS)-optical coherence tomography (OCT) system would be a better choice for interventional cardiologists. To validate the image quality and safety of the novel IVUS-OCT system for guiding coronary intervention in Chinese patients, a total of 114 cases were included. The proportion of clear imaging length was 96.21% ± 10.16%. Device success rate was 99.1%, technical success rate was 98.2%, and excellent image rate was 96.5%. No catheter-related adverse events occurred, and the incidence of device defects was 0.9%. This study preliminarily verified the image quality and safety of the novel Hybrid IVUS and OCT imaging system. (The StUdy to Evaluate the Performance and safEty of the Novasight HybRid System Using Objective PeRformance Criteria [SUPERIOR]; NCT04617899).

Authors

Institutions

Publication Details

Journal
JACC Asia
Published
2025-03-01
DOI
https://doi.org/10.1016/j.jacasi.2025.01.009
Citations
2
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
4.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Multicenter Feasibility and Safety Study of a Novel Hybrid IVUS-OCT Imaging System

Yicong Ye, Zhenhong Fu, Yupeng Wang, Xiaoling Zhang et al.
2 citations
JACC Asia
Coronary Interventions and Diagnostics
4.01
article

A Multicenter Feasibility and Safety Study of a Novel Hybrid IVUS-OCT Imaging System

Yicong Ye, Zhenhong Fu, Yupeng Wang, Xiaoling Zhang, Yundai Chen, Xinye Xu, Yida Tang, Yong Zeng, Qinhua Jin
article en
2 citations

Abstract

Currently, precise stent manipulation and placement in percutaneous coronary intervention remain compromised. Intravascular imaging techniques are often limited by either spatial resolution or depth of penetration. A hybrid intravascular ultrasound (IVUS)-optical coherence tomography (OCT) system would be a better choice for interventional cardiologists. To validate the image quality and safety of the novel IVUS-OCT system for guiding coronary intervention in Chinese patients, a total of 114 cases were included. The proportion of clear imaging length was 96.21% ± 10.16%. Device success rate was 99.1%, technical success rate was 98.2%, and excellent image rate was 96.5%. No catheter-related adverse events occurred, and the incidence of device defects was 0.9%. This study preliminarily verified the image quality and safety of the novel Hybrid IVUS and OCT imaging system. (The StUdy to Evaluate the Performance and safEty of the Novasight HybRid System Using Objective PeRformance Criteria [SUPERIOR]; NCT04617899).

JACC AsiaVol. 5(3)
Capital Medical University (CN), Peking University (CN), Chinese PLA General Hospital (CN), Beijing Anzhen Hospital (CN), Peking University Third Hospital (CN)
Openalex Percentile: Top 8%
Coronary Interventions and Diagnostics
4.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Multicenter Feasibility and Safety Study of a Novel Hybrid IVUS-OCT Imaging System — Yicong Ye, Zhenhong Fu, et al. · JACC Asia (2025) | TGRS Research Map | TGRS