Streamlining Molecular and Serology Laboratory Operations: A Lean Six Sigma Approach

Background The Lean Six Sigma tools are widely used in various industries, including healthcare, to reduce waste and improve quality. This study investigated how Lean Six Sigma might be used to improve quality control procedures in virology and molecular laboratories. The study intended to minimize errors, expedite laboratory procedures, and shorten turnaround times (TATs). Methods A prospective cross-sectional study was conducted at a tertiary care hospital located in India to assess the quality indicators for the processes in a virology laboratory and identify the wastes in those processes. By using the Define, Measure, Analyze, Improve, Control (DMAIC) strategy, the research quantified quality indicators like defects per million opportunities (DPMO) and six-sigma metrics. Subsequently, corrective measures were implemented to reduce the errors. A paired t-test was done by taking the sigma values of pre- and post-intervention phases. Results In the pre-analytical phase, a total of 6925 test requisition forms and 12,236 samples were considered, and the sigma value showed drastic improvement after the implementation of the DMAIC strategy. Similarly, in the analytical phase, out of a total of 61 samples, random errors showed an increase in sigma value from 1.71 to 2.47, and reagent contamination showed an increase in sigma value from 1.29 to 2.17. The type of error non-conformity with quality controls showed an increase in sigma value from 1.93 to 2.65, and systemic error showed an increase in sigma value from 2.88 to 3.7. A total of 126 samples were taken in the post-analytical phase, where transcription errors and TAT sigma value drastically increased (transcription error improved from a sigma value of 3.03 to a sigma value of 3.65, and TAT improved from a sigma value of 3.29 to a sigma value of 3.48) by DMAIC strategy. The two-tailed p-value was found to be 0.0269 (p < 0.05), which was statistically significant. Conclusions The study highlighted that error reduction directly correlated with a decrease in diagnostic mistakes. Misdiagnoses often lead to alternate treatment methods, causing delays in patient treatment management. Further, the errors reduce the efficiency of the hospital in terms of time and cost. Reducing unnecessary delays in the test process allows clinicians to focus on patient care. The statistical significance of the study showed the effectiveness of the interventions implemented in the study to practical outcomes like reduced misdiagnoses, cost savings, operational improvements, and strengthening the clinical relevance of the study. Further research is needed on these quality improvement steps for the adoptive process flow for the operation process of the laboratories in healthcare setups.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-03-04
DOI
https://doi.org/10.7759/cureus.80038
Primary Topic
Quality and Safety in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Streamlining Molecular and Serology Laboratory Operations: A Lean Six Sigma Approach

Swayamprava Dalai, Vikas Dutta, Ishani Bora, Rahul Kumar et al.
Cureus
Quality and Safety in Healthcare
article

Streamlining Molecular and Serology Laboratory Operations: A Lean Six Sigma Approach

Swayamprava Dalai, Vikas Dutta, Ishani Bora, Rahul Kumar, Rashmi Ranjan Guru, Meenakshi Sharma, B. Kumar, Subhodip Mitra, Sumit kumar Sangat, Prasad Bhanap
article en

Abstract

Background The Lean Six Sigma tools are widely used in various industries, including healthcare, to reduce waste and improve quality. This study investigated how Lean Six Sigma might be used to improve quality control procedures in virology and molecular laboratories. The study intended to minimize errors, expedite laboratory procedures, and shorten turnaround times (TATs). Methods A prospective cross-sectional study was conducted at a tertiary care hospital located in India to assess the quality indicators for the processes in a virology laboratory and identify the wastes in those processes. By using the Define, Measure, Analyze, Improve, Control (DMAIC) strategy, the research quantified quality indicators like defects per million opportunities (DPMO) and six-sigma metrics. Subsequently, corrective measures were implemented to reduce the errors. A paired t-test was done by taking the sigma values of pre- and post-intervention phases. Results In the pre-analytical phase, a total of 6925 test requisition forms and 12,236 samples were considered, and the sigma value showed drastic improvement after the implementation of the DMAIC strategy. Similarly, in the analytical phase, out of a total of 61 samples, random errors showed an increase in sigma value from 1.71 to 2.47, and reagent contamination showed an increase in sigma value from 1.29 to 2.17. The type of error non-conformity with quality controls showed an increase in sigma value from 1.93 to 2.65, and systemic error showed an increase in sigma value from 2.88 to 3.7. A total of 126 samples were taken in the post-analytical phase, where transcription errors and TAT sigma value drastically increased (transcription error improved from a sigma value of 3.03 to a sigma value of 3.65, and TAT improved from a sigma value of 3.29 to a sigma value of 3.48) by DMAIC strategy. The two-tailed p-value was found to be 0.0269 (p < 0.05), which was statistically significant. Conclusions The study highlighted that error reduction directly correlated with a decrease in diagnostic mistakes. Misdiagnoses often lead to alternate treatment methods, causing delays in patient treatment management. Further, the errors reduce the efficiency of the hospital in terms of time and cost. Reducing unnecessary delays in the test process allows clinicians to focus on patient care. The statistical significance of the study showed the effectiveness of the interventions implemented in the study to practical outcomes like reduced misdiagnoses, cost savings, operational improvements, and strengthening the clinical relevance of the study. Further research is needed on these quality improvement steps for the adoptive process flow for the operation process of the laboratories in healthcare setups.

CureusVol. 17(3)
Chandigarh University (IN), Safdarjang Hospital (IN), All India Institute of Medical Sciences Jodhpur (IN), Symbiosis International University (IN), Government Medical College and Hospital (IN), College of Medicine & JNM Hospital (IN), Post Graduate Institute of Medical Education and Research (IN)
Openalex Percentile: Top 92%
Quality and Safety in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.