High accuracy calibration method for 3D curve reconstruction based on a twisted multicore fiber

A high accuracy calibration method for three-dimensional (3D) curve reconstruction based on a twisted multicore fiber (MCF) is proposed and experimentally investigated. The core spacing, core azimuth, and twist bias of the twisted MCF are decoupled and calibrated according to the amplitude, phase, and period information derived from the strain curves. A 3D curve reconstruction experimental system based on the twisted MCF and optical frequency domain reflectometry (OFDR) is established, and the curve reconstruction performance is evaluated before and after calibration. The results show that, with a reconstruction length of 25 cm, the average tip position error is reduced from 28.12 to 2.50 mm.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2025-03-04
DOI
https://doi.org/10.1364/ol.555220
Citations
3
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
3.83

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High accuracy calibration method for 3D curve reconstruction based on a twisted multicore fiber

Keyuan Yang, Zikang Xv, Deming Liu, Changjian Ke et al.
3 citations
Optics Letters
Optical measurement and interference techniques
3.83
article

High accuracy calibration method for 3D curve reconstruction based on a twisted multicore fiber

Keyuan Yang, Zikang Xv, Deming Liu, Changjian Ke, Zhihao Wang
article en
3 citations

Abstract

A high accuracy calibration method for three-dimensional (3D) curve reconstruction based on a twisted multicore fiber (MCF) is proposed and experimentally investigated. The core spacing, core azimuth, and twist bias of the twisted MCF are decoupled and calibrated according to the amplitude, phase, and period information derived from the strain curves. A 3D curve reconstruction experimental system based on the twisted MCF and optical frequency domain reflectometry (OFDR) is established, and the curve reconstruction performance is evaluated before and after calibration. The results show that, with a reconstruction length of 25 cm, the average tip position error is reduced from 28.12 to 2.50 mm.

Optics LettersVol. 50(6)
Wuhan National Laboratory for Optoelectronics (CN)
National Natural Science Foundation of China
Sustainable cities and communities
Openalex Percentile: Top 8%
Optical measurement and interference techniques
3.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.