Performance Evaluation of the Sysmex XN50 Slide-Maker-Stainer

Automated equipment has many benefits but analytical assessment of instrument is required for laboratory usage. This study evaluates the performance of Sysmex XN-50 slide-maker and stainer compared to manual technique. The primary goal of the study was to evaluate smear’s quality. Additionally, carry-over, repeatability, comparability using Passing Bablok Regression for white blood cells then sensitivity and specificity for red blood cells and platelets. Smear’s quality was acceptable except for one. There was no carry-over on the Sysmex XN50. Repeatability showed acceptable results. There was good agreement on white blood cells differential count including abnormal cells between blood films by the Sysmex XN50 and manually prepared blood films. Red blood cells and platelets were also comparable, the results were excellent, with sensitivity and specificity being very high. The results obtained in this study show the quality of the Sysmex XN50 device in a laboratory, it offers advantages due to its reliability and speed of preparation of blood smears.

Authors

Publication Details

Journal
Saudi Journal of Medicine
Published
2025-03-01
DOI
https://doi.org/10.36348/sjm.2025.v10i03.002
Citations
1
Primary Topic
Manufacturing Process and Optimization
Type
article
Field-Weighted Citation Impact
1.24
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Evaluation of the Sysmex XN50 Slide-Maker-Stainer

Salma Rouhi, Wafae Quiddi, Sanae Sayagh, Ouijdane Kajjoune et al.
1 citations
Saudi Journal of Medicine
Manufacturing Process and Optimization
1.24
article

Performance Evaluation of the Sysmex XN50 Slide-Maker-Stainer

Salma Rouhi, Wafae Quiddi, Sanae Sayagh, Ouijdane Kajjoune, Anass Sakhi
article en
1 citations

Abstract

Automated equipment has many benefits but analytical assessment of instrument is required for laboratory usage. This study evaluates the performance of Sysmex XN-50 slide-maker and stainer compared to manual technique. The primary goal of the study was to evaluate smear’s quality. Additionally, carry-over, repeatability, comparability using Passing Bablok Regression for white blood cells then sensitivity and specificity for red blood cells and platelets. Smear’s quality was acceptable except for one. There was no carry-over on the Sysmex XN50. Repeatability showed acceptable results. There was good agreement on white blood cells differential count including abnormal cells between blood films by the Sysmex XN50 and manually prepared blood films. Red blood cells and platelets were also comparable, the results were excellent, with sensitivity and specificity being very high. The results obtained in this study show the quality of the Sysmex XN50 device in a laboratory, it offers advantages due to its reliability and speed of preparation of blood smears.

Saudi Journal of MedicineVol. 10(03)
Openalex Percentile: Top 22%
Manufacturing Process and Optimization
1.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance Evaluation of the Sysmex XN50 Slide-Maker-Stainer — Salma Rouhi, Wafae Quiddi, et al. · Saudi Journal of Medicine (2025) | TGRS Research Map | TGRS