Full-image operation of fast charge exchange recombination spectroscopy with high-spatial and high-wavelength resolutions in large helical device

Aiming at fully utilizing the spatial resolution of a fast charge exchange recombination spectroscopy (CXS) system, a full-image operation scenario is newly developed. A data analysis procedure is presented. Calibration using a white light source and a neon-enclosed hollow cathode lamp is performed, which provides vertical-stripe separation, horizontal-pixel vs wavelength conversion, and stripe sensitivity. Data from fast and slow CXS systems are compared, providing qualitatively equivalent emission spectra in the same time-integration duration. An asymptotically decreasing trend of noise level with respect to the amount of ensemble averaging (time integration) is confirmed for the fast CXS system. Radial profiles of emission intensity, ion temperature, and toroidal velocity obtained from slow and fast CXS systems are compared, and reasonable agreement is found.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-03-01
DOI
https://doi.org/10.1063/5.0251924
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Full-image operation of fast charge exchange recombination spectroscopy with high-spatial and high-wavelength resolutions in large helical device

T. Kobayashi, M. Yoshinuma, K. Ida
Review of Scientific Instruments
Spectroscopy and Laser Applications
article

Full-image operation of fast charge exchange recombination spectroscopy with high-spatial and high-wavelength resolutions in large helical device

T. Kobayashi, M. Yoshinuma, K. Ida
article en

Abstract

Aiming at fully utilizing the spatial resolution of a fast charge exchange recombination spectroscopy (CXS) system, a full-image operation scenario is newly developed. A data analysis procedure is presented. Calibration using a white light source and a neon-enclosed hollow cathode lamp is performed, which provides vertical-stripe separation, horizontal-pixel vs wavelength conversion, and stripe sensitivity. Data from fast and slow CXS systems are compared, providing qualitatively equivalent emission spectra in the same time-integration duration. An asymptotically decreasing trend of noise level with respect to the amount of ensemble averaging (time integration) is confirmed for the fast CXS system. Radial profiles of emission intensity, ion temperature, and toroidal velocity obtained from slow and fast CXS systems are compared, and reasonable agreement is found.

Review of Scientific InstrumentsVol. 96(3)
Kyushu University (JP), National Institutes of Natural Sciences (JP), The Graduate University for Advanced Studies, SOKENDAI (JP), National Institute for Fusion Science (JP)
Japan Society for the Promotion of Science
Affordable and clean energy
Openalex Percentile: Top 96%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.