Development and Validation of a High-Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry Method for the Simultaneous Determination of Arsenic and Mercury Species in Human Urine

The simultaneous determination of arsenic and mercury species in human urine is critical for clinical diagnostics and therapeutic monitoring because it reduces the costs, time, and consumption of samples. This study proposes a method of utilizing high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) for the concurrent analysis of arsenic and mercury species in urine samples. The separation was performed using a Hepu AR 5 μm C18 (250 × 4.6 mm) column, employing a mobile phase composed of 0.1% L-cysteine, 5 mM NH4H2PO4, and 4 mM tetrabutylammonium hydroxide (TBAH). The samples were diluted with water, and matrix interference was reduced through the application of a kinetic energy discrimination (KED) mode. Calibration curves for four arsenic species and three mercury species exhibited strong linearity within the range of 1–20 μg L−1, with correlation coefficients (r) above 0.999. The limits of detection (LOD) ranged from 0.030 to 0.086 μg L−1, while the limits of quantitation (LOQ) were observed to range from 0.10 to 0.29 μg L−1. The spiking recoveries for all species varied from 87.0% to 110.3%, and the intra-day and inter-day relative standard deviations (RSD) were determined to be 1.1–6.0%, and 0.8–9.2%, respectively. These results indicate that the developed method achieves high precision, accuracy, and suitability for clinical applications, offering valuable insights for the diagnosis and treatment of heavy metal exposure.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2025-03-01
DOI
https://doi.org/10.3390/chemosensors13030078
Citations
6
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
4.51

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of a High-Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry Method for the Simultaneous Determination of Arsenic and Mercury Species in Human Urine

Ying Tan, Luxuan Wang, Haitao Shen, Xiaodong Pan et al.
6 citations
Chemosensors
Analytical chemistry methods development
4.51
article

Development and Validation of a High-Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry Method for the Simultaneous Determination of Arsenic and Mercury Species in Human Urine

Ying Tan, Luxuan Wang, Haitao Shen, Xiaodong Pan, Jingshun Zhang, Jun Tang, Pinggu Wu, Zhengyan Hu, Chenyang Zheng
article en
6 citations

Abstract

The simultaneous determination of arsenic and mercury species in human urine is critical for clinical diagnostics and therapeutic monitoring because it reduces the costs, time, and consumption of samples. This study proposes a method of utilizing high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) for the concurrent analysis of arsenic and mercury species in urine samples. The separation was performed using a Hepu AR 5 μm C18 (250 × 4.6 mm) column, employing a mobile phase composed of 0.1% L-cysteine, 5 mM NH4H2PO4, and 4 mM tetrabutylammonium hydroxide (TBAH). The samples were diluted with water, and matrix interference was reduced through the application of a kinetic energy discrimination (KED) mode. Calibration curves for four arsenic species and three mercury species exhibited strong linearity within the range of 1–20 μg L−1, with correlation coefficients (r) above 0.999. The limits of detection (LOD) ranged from 0.030 to 0.086 μg L−1, while the limits of quantitation (LOQ) were observed to range from 0.10 to 0.29 μg L−1. The spiking recoveries for all species varied from 87.0% to 110.3%, and the intra-day and inter-day relative standard deviations (RSD) were determined to be 1.1–6.0%, and 0.8–9.2%, respectively. These results indicate that the developed method achieves high precision, accuracy, and suitability for clinical applications, offering valuable insights for the diagnosis and treatment of heavy metal exposure.

ChemosensorsVol. 13(3)
Zhejiang Center for Disease Control and Prevention (CN)
Medical Science and Technology Project of Zhejiang Province
Openalex Percentile: Top 6%
Analytical chemistry methods development
4.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.