Research on smart substation protection assessment method considering multiple failure factors

Neglecting implicit failure factors leads to a large deviation between the failure to operate (FTO) frequency obtained from the reliability assessment of the existing smart substation protection system and the grid statistics. For this reason, this paper proposes a new protection assessment method. First, the reliability model of the protection system is established, taking into account the repairability of the protection system and the implicit failure factors. Then, based on the time series Monte-Carlo method, the reliability model is solved to obtain the protection system failure probability and FTO frequency. The simulation results show that the FTO frequency of the protection system obtained by considering multiple failure factors is more consistent with the grid statistics, and improving the self-test performance of the protection equipment can significantly improve the reliability of the protection system.

Authors

Institutions

Publication Details

Published
2024-12-29
DOI
https://doi.org/10.1109/iceace63551.2024.10898670
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on smart substation protection assessment method considering multiple failure factors

Yanjing Zhang, Xionghui He, Weijie Huang, Wei Yang et al.
Power Systems Fault Detection
article

Research on smart substation protection assessment method considering multiple failure factors

Yanjing Zhang, Xionghui He, Weijie Huang, Wei Yang, Rui Wang, Dongbin Yu
article en

Abstract

Neglecting implicit failure factors leads to a large deviation between the failure to operate (FTO) frequency obtained from the reliability assessment of the existing smart substation protection system and the grid statistics. For this reason, this paper proposes a new protection assessment method. First, the reliability model of the protection system is established, taking into account the repairability of the protection system and the implicit failure factors. Then, based on the time series Monte-Carlo method, the reliability model is solved to obtain the protection system failure probability and FTO frequency. The simulation results show that the FTO frequency of the protection system obtained by considering multiple failure factors is more consistent with the grid statistics, and improving the self-test performance of the protection equipment can significantly improve the reliability of the protection system.

Beijing Automotive Group (China) (CN), China Southern Power Grid (China) (CN)
Openalex Percentile: Top 65%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.