Robotic Spine Surgery - Surgical technique and nuances for improving safety

The integration of robotic technology into spinal surgery has led to a remarkable transformation, offering improved precision and safety. The "CT-Fluoro merge" and "Scan-and-Plan" methods for pedicle screw application promise numerous advantages, minimizing risks associated with traditional approaches. Our early series of patients who underwent robot-assisted pedicle screw placements for various indications, predominantly lumbar spondylosis, revealed no complications related to screws, neurological deficits, or unplanned returns to the operating theatre, thus emphasizing the safety and effectiveness of the robot. Studies have consistently demonstrated the superiority of robot-assisted pedicle screw placement in terms of accuracy, with decreasing rates of technical issues indicating improvements in reliability and precision. Our experiences align with these findings, signalling the emergence of robotic spine surgery as the forthcoming standard of care in the field. This short communication explores the steps involved in robotic pedicle screw placement, discusses nuances for improving safety, and emphasizes its benefits and implications for the future of spinal care.

Authors

Institutions

Publication Details

Journal
Biomedicine
Published
2025-02-27
DOI
https://doi.org/10.37796/2211-8039.1644
Citations
2
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robotic Spine Surgery - Surgical technique and nuances for improving safety

Arun-Kumar Kaliya-Perumal, Jacob Yoong-Leong Oh, Pirateb Paramasivam Meenakshi Sundaram, Mun Chun Lai
2 citations
Biomedicine
Medical Imaging and Analysis
1.35
article

Robotic Spine Surgery - Surgical technique and nuances for improving safety

Arun-Kumar Kaliya-Perumal, Jacob Yoong-Leong Oh, Pirateb Paramasivam Meenakshi Sundaram, Mun Chun Lai
article en
2 citations

Abstract

The integration of robotic technology into spinal surgery has led to a remarkable transformation, offering improved precision and safety. The "CT-Fluoro merge" and "Scan-and-Plan" methods for pedicle screw application promise numerous advantages, minimizing risks associated with traditional approaches. Our early series of patients who underwent robot-assisted pedicle screw placements for various indications, predominantly lumbar spondylosis, revealed no complications related to screws, neurological deficits, or unplanned returns to the operating theatre, thus emphasizing the safety and effectiveness of the robot. Studies have consistently demonstrated the superiority of robot-assisted pedicle screw placement in terms of accuracy, with decreasing rates of technical issues indicating improvements in reliability and precision. Our experiences align with these findings, signalling the emergence of robotic spine surgery as the forthcoming standard of care in the field. This short communication explores the steps involved in robotic pedicle screw placement, discusses nuances for improving safety, and emphasizes its benefits and implications for the future of spinal care.

BiomedicineVol. 15(1)
Nanyang Technological University (SG), Tan Tock Seng Hospital (SG)
Openalex Percentile: Top 22%
Medical Imaging and Analysis
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Robotic Spine Surgery - Surgical technique and nuances for improving safety — Arun-Kumar Kaliya-Perumal, Jacob Yoong-Leong Oh, et al. · Biomedicine (2025) | TGRS Research Map | TGRS