Spectrofluorimetric Technique Creation and Approval for Cabotegravir Estimate in Dose Formats for Medications

The current investigation sought to create and approve specific spectrofluorimetric technique to cabotegravir estimate in dose formats for medications. The relative fluorescence intensity for the cabotegravir was measured at a wavelength of excitation of 395nm and wavelength of emission at 484nm. There was a linear response with a correlation coefficient of 0.999 between 5 and 25µg/ml. Developed technique was supported with the various validation parameters such as accuracy, sensitivity, specificity, and precision in keeping with the ICH recommendations. The devised approach was shown to be sensitive, the corresponding quantification and detection limits of 0.6 µg/ml and 0.21 µg/ml. The found results indicates the method developed for the estimation of cabotegravir were specific, accurate, precise and reproducible. Finally, it can be concluded that this spectrofluorimetric method could be used in routine analysis for cabotegravir estimate in dose formats for medications.

Authors

Institutions

Publication Details

Journal
Oriental Journal Of Chemistry
Published
2025-02-28
DOI
https://doi.org/10.13005/ojc/410126
Citations
1
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spectrofluorimetric Technique Creation and Approval for Cabotegravir Estimate in Dose Formats for Medications

Panikumar Durga Anumolu, Ashok Gorja, Jahnavi Bandla, Santhoshi Abbineni
1 citations
Oriental Journal Of Chemistry
Analytical Methods in Pharmaceuticals
0.75
article

Spectrofluorimetric Technique Creation and Approval for Cabotegravir Estimate in Dose Formats for Medications

Panikumar Durga Anumolu, Ashok Gorja, Jahnavi Bandla, Santhoshi Abbineni
article en
1 citations

Abstract

The current investigation sought to create and approve specific spectrofluorimetric technique to cabotegravir estimate in dose formats for medications. The relative fluorescence intensity for the cabotegravir was measured at a wavelength of excitation of 395nm and wavelength of emission at 484nm. There was a linear response with a correlation coefficient of 0.999 between 5 and 25µg/ml. Developed technique was supported with the various validation parameters such as accuracy, sensitivity, specificity, and precision in keeping with the ICH recommendations. The devised approach was shown to be sensitive, the corresponding quantification and detection limits of 0.6 µg/ml and 0.21 µg/ml. The found results indicates the method developed for the estimation of cabotegravir were specific, accurate, precise and reproducible. Finally, it can be concluded that this spectrofluorimetric method could be used in routine analysis for cabotegravir estimate in dose formats for medications.

Oriental Journal Of ChemistryVol. 41(1)
Institute of Chartered Financial Analysts of India (IN)
Openalex Percentile: Top 35%
Analytical Methods in Pharmaceuticals
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.