Detection of Open-Neutral Fault in Low-Voltage Distribution Systems Based on Third Harmonic Energy Variation

Detecting open-neutral faults in low-voltage distribution systems is essential for ensuring system stability and protecting electrical equipment from potentially hazardous conditions such as over-voltage and under-voltage. Open-neutral faults, common in areas with load imbalances, can lead to significant safety risks, making accurate detection methods crucial. This paper introduces a novel detection approach based on variations in third harmonic energy. In the three-phase fourwire system without disconnection faults, the neutral wire channels third harmonic currents from nonlinear loads to the ground. However, when the neutral wire is disconnected, these currents are redirected to other loads, resulting in measurable shifts in third harmonic energy. By analyzing these energy fluctuations before and after a fault and applying set thresholds to distinguish faults from normal load variations, the proposed method effectively identifies open-neutral faults. Simulation results demonstrate high detection accuracy under various load conditions, even when load balance is maintained.

Authors

Institutions

Publication Details

Published
2024-12-20
DOI
https://doi.org/10.1109/ceect63656.2024.10898533
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Open-Neutral Fault in Low-Voltage Distribution Systems Based on Third Harmonic Energy Variation

Zhongtian Zhang, Xiaoqiang Chang, Lujin Wang, Zhihua Zhang et al.
Power Systems Fault Detection
article

Detection of Open-Neutral Fault in Low-Voltage Distribution Systems Based on Third Harmonic Energy Variation

Zhongtian Zhang, Xiaoqiang Chang, Lujin Wang, Zhihua Zhang, Meiyang Shao
article en

Abstract

Detecting open-neutral faults in low-voltage distribution systems is essential for ensuring system stability and protecting electrical equipment from potentially hazardous conditions such as over-voltage and under-voltage. Open-neutral faults, common in areas with load imbalances, can lead to significant safety risks, making accurate detection methods crucial. This paper introduces a novel detection approach based on variations in third harmonic energy. In the three-phase fourwire system without disconnection faults, the neutral wire channels third harmonic currents from nonlinear loads to the ground. However, when the neutral wire is disconnected, these currents are redirected to other loads, resulting in measurable shifts in third harmonic energy. By analyzing these energy fluctuations before and after a fault and applying set thresholds to distinguish faults from normal load variations, the proposed method effectively identifies open-neutral faults. Simulation results demonstrate high detection accuracy under various load conditions, even when load balance is maintained.

Xi'an Jiaotong University (CN)
Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 65%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detection of Open-Neutral Fault in Low-Voltage Distribution Systems Based on Third Harmonic Energy Variation — Zhongtian Zhang, Xiaoqiang Chang, et al. · (2024) | TGRS Research Map | TGRS