Electrochemical Study of Carminic Acid Determination in Foodstuffs. Investigation of the Reaction Mechanism and Electrochemical Parameters

A new electrochemical sensor was designed to discriminate and determine Carminic Acid (CA) utilizing a glassy carbon electrode (GCE) modified with multi-walled carbon nanotubes (MWCNTs). Using this electrode, CA showed an anodic peak at around 0.24 V. The mechanism of the electrochemical process on the surface of the modified electrode was analyzed by obtaining cyclic voltammograms at various potential scan rates. Different electrochemical parameters of present experiments were calculated such as charge transfer coefficient α as 0.46 and diffusion coefficient D as 3.25 × 10–7 cm2 s–1. After studying the electrocatalytic behavior of the CA, differential-pulse voltammetry (DPV) was subsequently applied as a very sensitive electro-analytical method for the determination of sub-micromolar amounts of CA. Under the optimized conditions, the anodic peak current enhanced with the CA between 0.41 to 5.55 µM. The detection limit was calculated to be 0.24 µM (S/N = 3). The modified electrode was successfully applied for the accurate determination of minor amounts of CA in strawberry milk samples with adequate results.

Authors

Institutions

Publication Details

Journal
Russian Journal of Electrochemistry
Published
2024-12-01
DOI
https://doi.org/10.1134/s1023193524700599
Citations
3
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Study of Carminic Acid Determination in Foodstuffs. Investigation of the Reaction Mechanism and Electrochemical Parameters

Marzieh Lotfi, Esmaeel Alipour, Habibeh Shahabi
3 citations
Russian Journal of Electrochemistry
Advanced Chemical Sensor Technologies
0.55
article

Electrochemical Study of Carminic Acid Determination in Foodstuffs. Investigation of the Reaction Mechanism and Electrochemical Parameters

Marzieh Lotfi, Esmaeel Alipour, Habibeh Shahabi
article en
3 citations

Abstract

A new electrochemical sensor was designed to discriminate and determine Carminic Acid (CA) utilizing a glassy carbon electrode (GCE) modified with multi-walled carbon nanotubes (MWCNTs). Using this electrode, CA showed an anodic peak at around 0.24 V. The mechanism of the electrochemical process on the surface of the modified electrode was analyzed by obtaining cyclic voltammograms at various potential scan rates. Different electrochemical parameters of present experiments were calculated such as charge transfer coefficient α as 0.46 and diffusion coefficient D as 3.25 × 10–7 cm2 s–1. After studying the electrocatalytic behavior of the CA, differential-pulse voltammetry (DPV) was subsequently applied as a very sensitive electro-analytical method for the determination of sub-micromolar amounts of CA. Under the optimized conditions, the anodic peak current enhanced with the CA between 0.41 to 5.55 µM. The detection limit was calculated to be 0.24 µM (S/N = 3). The modified electrode was successfully applied for the accurate determination of minor amounts of CA in strawberry milk samples with adequate results.

Russian Journal of ElectrochemistryVol. 60(12)
University of Tabriz (IR)
Zero hunger
Openalex Percentile: Top 35%
Advanced Chemical Sensor Technologies
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.