Evaluation of the Color Change Characteristics of UV LABELs Under Vacuum Ultraviolet Irradiation from a Xenon Excimer Lamp for Matting Process
This study evaluated the color change characteristics of commercial UV LABEL™s to monitor VUV irradiation dose from an excimer lamp in a nitrogen atmosphere for decorative matting process. Among UV LABELs, UV-S demonstrated high sensitivity without saturation up to 100 mJ/cm2, enabling precise VUV irradiation dose control via a calibration curve, however, illuminance-dependent corrections are required for accurate monitoring.
Authors
- Akihiro Shimizu (ORCID: https://orcid.org/0000-0001-9392-2087)
Institutions
- Ushio (Japan) (JP)
- Gifu University (JP)
Publication Details
- Journal
- Journal of The Surface Finishing Society of Japan
- Published
- 2025-03-01
- DOI
- https://doi.org/10.4139/sfj.76.148
- Primary Topic
- Pigment Synthesis and Properties
- Type
- article
- Field-Weighted Citation Impact
- 0.00