Control system for an underwater coded aperture miniature mass spectrometer

• Development of control electronics for an underwater cycloidal coded aperture miniature mass spectrometer • Programmable electron emission controller for an electron ionization source • Control electronics performance matches that using laboratory source measure units In situ measurements of the spatiotemporal distribution of dissolved gases in the ocean are useful for a wide variety of applications including monitoring biogeochemical cycles ( e.g. , methane, oxygen, and carbon dioxide fluxes), detecting pollutants, studying submarine groundwater discharge, and tracking chemical gradients in water columns or sediment interfaces. Over the past two decades, underwater membrane inlet mass spectrometry has emerged as a leading technology for in situ dissolved gas analysis, leveraging various mass analyzers such as quadrupole, ion trap, and cycloidal systems. While quadrupoles and ion traps face challenges such as water vapor interference and resolution limitations, cycloidal analyzers offer higher resolution at low mass-to-charge ratios with reduced power requirements. However, they have historically suffered from sensitivity and sequential analysis limitations. Recent advances, including ion array detectors and computational sensing, now enable simultaneous mass detection and improved sensitivity in cycloidal mass analyzers. This study introduces the development of an underwater coded aperture miniature mass spectrometer (UW-CAMMS), incorporating a cycloidal mass analyzer, ion array detector, and spatially coded apertures. A low-power electronic control system for the UW-CAMMS is designed and characterized, with performance comparable to laboratory-based systems, showcasing progress toward efficient, compact underwater dissolved gas monitoring. This technology can be used to study dynamic processes in marine, freshwater, and brackish systems with high spatial and temporal resolution.

Authors

Institutions

Publication Details

Journal
Green Analytical Chemistry
Published
2025-03-02
DOI
https://doi.org/10.1016/j.greeac.2025.100241
Primary Topic
Methane Hydrates and Related Phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Control system for an underwater coded aperture miniature mass spectrometer

Justin Keogh, Stefan M. Goetz, Charles B. Parker, Jeffrey T. Glass et al.
Green Analytical Chemistry
Methane Hydrates and Related Phenomena
article

Control system for an underwater coded aperture miniature mass spectrometer

Justin Keogh, Stefan M. Goetz, Charles B. Parker, Jeffrey T. Glass, Jason J. Amsden, Rafael Bento Serpa, Nicolas Cassar, Harold F. Hemond, M. Bonner Denton, Thomas Jablonski
article en

Abstract

• Development of control electronics for an underwater cycloidal coded aperture miniature mass spectrometer • Programmable electron emission controller for an electron ionization source • Control electronics performance matches that using laboratory source measure units In situ measurements of the spatiotemporal distribution of dissolved gases in the ocean are useful for a wide variety of applications including monitoring biogeochemical cycles ( e.g. , methane, oxygen, and carbon dioxide fluxes), detecting pollutants, studying submarine groundwater discharge, and tracking chemical gradients in water columns or sediment interfaces. Over the past two decades, underwater membrane inlet mass spectrometry has emerged as a leading technology for in situ dissolved gas analysis, leveraging various mass analyzers such as quadrupole, ion trap, and cycloidal systems. While quadrupoles and ion traps face challenges such as water vapor interference and resolution limitations, cycloidal analyzers offer higher resolution at low mass-to-charge ratios with reduced power requirements. However, they have historically suffered from sensitivity and sequential analysis limitations. Recent advances, including ion array detectors and computational sensing, now enable simultaneous mass detection and improved sensitivity in cycloidal mass analyzers. This study introduces the development of an underwater coded aperture miniature mass spectrometer (UW-CAMMS), incorporating a cycloidal mass analyzer, ion array detector, and spatially coded apertures. A low-power electronic control system for the UW-CAMMS is designed and characterized, with performance comparable to laboratory-based systems, showcasing progress toward efficient, compact underwater dissolved gas monitoring. This technology can be used to study dynamic processes in marine, freshwater, and brackish systems with high spatial and temporal resolution.

Green Analytical ChemistryVol. 13
University of Arizona (US), Duke University (US), Massachusetts Institute of Technology (US)
National Science Foundation
Openalex Percentile: Top 97%
Methane Hydrates and Related Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.