METHOD FOR UNIFORMIZING MAXIMUM INTER-STORY DRIFT ANGLE OF MULTIPLE SEISMIC RESPONSES IN ELASTIC EQUIVALENT SHEAR-SPRING MODEL WITH UNTUNED INERTIAL MASS DAMPER

This paper discusses a method for uniformizing the maximum inter-story drift angle of multiple seismic responses in elastic equivalent shear-spring models with untuned inertial mass dampers. First, the author proposes using pseudo-equivalent stiffness to assess the effect of untuned inertial mass dampers. Then, this pseudo-equivalent stiffness is applied to the method using closed-form representations of the primary mode, confirming the effectiveness of the control strategy for untuned inertial mass dampers. This allows for comparison with the damping effects of viscous dampers and demonstrates the potential for a wide range of applications of untuned inertial mass dampers.

Authors

Institutions

Publication Details

Journal
Journal of Structural and Construction Engineering (Transactions of AIJ)
Published
2025-02-28
DOI
https://doi.org/10.3130/aijs.90.314
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

METHOD FOR UNIFORMIZING MAXIMUM INTER-STORY DRIFT ANGLE OF MULTIPLE SEISMIC RESPONSES IN ELASTIC EQUIVALENT SHEAR-SPRING MODEL WITH UNTUNED INERTIAL MASS DAMPER

Mitsuo Suzuki
Journal of Structural and Construction Engineering (Transactions of AIJ)
Vibration Control and Rheological Fluids
article

METHOD FOR UNIFORMIZING MAXIMUM INTER-STORY DRIFT ANGLE OF MULTIPLE SEISMIC RESPONSES IN ELASTIC EQUIVALENT SHEAR-SPRING MODEL WITH UNTUNED INERTIAL MASS DAMPER

Mitsuo Suzuki
article en

Abstract

This paper discusses a method for uniformizing the maximum inter-story drift angle of multiple seismic responses in elastic equivalent shear-spring models with untuned inertial mass dampers. First, the author proposes using pseudo-equivalent stiffness to assess the effect of untuned inertial mass dampers. Then, this pseudo-equivalent stiffness is applied to the method using closed-form representations of the primary mode, confirming the effectiveness of the control strategy for untuned inertial mass dampers. This allows for comparison with the damping effects of viscous dampers and demonstrates the potential for a wide range of applications of untuned inertial mass dampers.

Journal of Structural and Construction Engineering (Transactions of AIJ)Vol. 90(829)
Azbil (Japan) (JP)
Sustainable cities and communities
Openalex Percentile: Top 96%
Vibration Control and Rheological Fluids
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.