Comparing methods to measure the dispersion of breathing parameters during exercise testing: A simulation study based on real‐life parameters from patients with dysfunctional breathing

The dispersion of the tidal volume and of the breathing frequency have been used to diagnose dysfunctional breathing during cardio-pulmonary exercise testing. No validated methods to objectively describe this dispersion exist. We aimed to validate such a method. We used simulations based on real-life parameters. Moving standard deviation (MSD) and residuals from locally estimated scatterplot smoothing (LOESS) were evaluated. The precision and the bias of each tested method at rest and during exercise simulations, with and without sighs, were measured. For LOESS, a 2nd degree polynomial was used, and different spans were tested (LOESS<sub>1</sub>, LOESS<sub>0.75</sub>, and LOESS<sub>0.5</sub>). For MSD, different number of points used for the calculation were tested (MSD<sub>7</sub>, MSD<sub>11</sub>, MSD<sub>15</sub>, and MSD19). The LOESS method was globally more precise, had less bias, and was less influenced by the trend as compared to MSD in almost all simulations except for extremely low dispersion combined with extreme trends. LOESS<sub>0.75</sub> had intermediate bias and precision between LOESS<sub>0.5</sub> and LOESS<sub>1</sub> in all simulations. LOESS<sub>0.75</sub> is a method that combines high precision, low bias, and low influenceability of trends. It could be considered as the method of choice to evaluate the dispersion of breathing parameters during cardiopulmonary exercise testing.

Authors

Institutions

Publication Details

Journal
Physiological Reports
Published
2025-02-28
DOI
https://doi.org/10.14814/phy2.70233
Citations
3
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
4.16
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing methods to measure the dispersion of breathing parameters during exercise testing: A simulation study based on real‐life parameters from patients with dysfunctional breathing

Pierantonio Laveneziana, Isabelle Frésard, Pierre‐Olivier Bridevaux, Aurélien Bringard et al.
3 citations
Physiological Reports
Heart Rate Variability and Autonomic Control
4.16
article

Comparing methods to measure the dispersion of breathing parameters during exercise testing: A simulation study based on real‐life parameters from patients with dysfunctional breathing

Pierantonio Laveneziana, Isabelle Frésard, Pierre‐Olivier Bridevaux, Aurélien Bringard, Ivan Guerreiro, Roberto Desponds, Marco Altarelli, Antoine Beurnier, Frédéric Lador, Cyril Jaksic, Anne Bergeron, Léon Genecand, Chloé Cantero, David Montani, Gaëtan Simian, Sara Thorens
article en
3 citations

Abstract

The dispersion of the tidal volume and of the breathing frequency have been used to diagnose dysfunctional breathing during cardio-pulmonary exercise testing. No validated methods to objectively describe this dispersion exist. We aimed to validate such a method. We used simulations based on real-life parameters. Moving standard deviation (MSD) and residuals from locally estimated scatterplot smoothing (LOESS) were evaluated. The precision and the bias of each tested method at rest and during exercise simulations, with and without sighs, were measured. For LOESS, a 2nd degree polynomial was used, and different spans were tested (LOESS<sub>1</sub>, LOESS<sub>0.75</sub>, and LOESS<sub>0.5</sub>). For MSD, different number of points used for the calculation were tested (MSD<sub>7</sub>, MSD<sub>11</sub>, MSD<sub>15</sub>, and MSD19). The LOESS method was globally more precise, had less bias, and was less influenced by the trend as compared to MSD in almost all simulations except for extremely low dispersion combined with extreme trends. LOESS<sub>0.75</sub> had intermediate bias and precision between LOESS<sub>0.5</sub> and LOESS<sub>1</sub> in all simulations. LOESS<sub>0.75</sub> is a method that combines high precision, low bias, and low influenceability of trends. It could be considered as the method of choice to evaluate the dispersion of breathing parameters during cardiopulmonary exercise testing.

Physiological ReportsVol. 13(5)
University of Geneva (CH), Inserm (FR), Université Paris-Saclay (FR), Sorbonne Université (FR), Hôpital Beau-Séjour (CH), Assistance Publique – Hôpitaux de Paris (FR), Hypertension pulmonaire : physiopathologie et innovation thérapeutique (FR), Hôpital du Valais (CH), Bicêtre Hospital (FR), Neurophysiologie respiratoire expérimentale et clinique
Life below water
Openalex Percentile: Top 7%
Heart Rate Variability and Autonomic Control
4.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.