Validation of a whole blood coagulometer sensitive to the direct oral anticoagulants

Readily available and rapid turn-around, bedside assays to measure the effect of the direct oral anticoagulants (DOACs) are not available. This study evaluates a point-of-care (PoC) coagulometer to assess the anticoagulant effects of the DOACs and low molecular weight heparin. Studies were done in fresh spiked blood from healthy volunteers. PoC coagulometer baseline clotting times were half that of the manual whole blood clotting time (WBCT, legacy method) and exhibited a sensitivity to DOAC anticoagulation approximately twice that of WBCT. All %CV values for both methods were < 10% with most being < 5% indicating acceptable precision of both methods. R<sup>2</sup> values for both clotting time and percent rise from baseline were > 0.98 indicating a strong correlation between the two methods. Replicate measurements for all subjects showed a maximum upper %CV value of 5.56% and a maximum upper value of all absolute %Differences of 5.5%, with both criteria meeting predefined acceptance criteria. The dose-response curves for all subjects were linear across the concentration ranges tested. The Perosphere Technology PoC coagulometer detects a range of therapeutic levels of the DOACs apixaban, rivaroxaban, edoxaban, and dabigatran, as well as the low molecular weight heparin, enoxaparin, with high precision and sensitivity. Please check and confirm the processed affiliations are correct . and amend if necessary.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-03-01
DOI
https://doi.org/10.1038/s41598-025-92201-7
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of a whole blood coagulometer sensitive to the direct oral anticoagulants

Daryl Mootoo, Jack Ansell, Sasha Bakhru, Stefan Zappe et al.
Scientific Reports
Hemodynamic Monitoring and Therapy
article

Validation of a whole blood coagulometer sensitive to the direct oral anticoagulants

Daryl Mootoo, Jack Ansell, Sasha Bakhru, Stefan Zappe, Lirong Chen, Xuan Jiang, Kelly Kronen, Dardan Osmani
article en

Abstract

Readily available and rapid turn-around, bedside assays to measure the effect of the direct oral anticoagulants (DOACs) are not available. This study evaluates a point-of-care (PoC) coagulometer to assess the anticoagulant effects of the DOACs and low molecular weight heparin. Studies were done in fresh spiked blood from healthy volunteers. PoC coagulometer baseline clotting times were half that of the manual whole blood clotting time (WBCT, legacy method) and exhibited a sensitivity to DOAC anticoagulation approximately twice that of WBCT. All %CV values for both methods were < 10% with most being < 5% indicating acceptable precision of both methods. R<sup>2</sup> values for both clotting time and percent rise from baseline were > 0.98 indicating a strong correlation between the two methods. Replicate measurements for all subjects showed a maximum upper %CV value of 5.56% and a maximum upper value of all absolute %Differences of 5.5%, with both criteria meeting predefined acceptance criteria. The dose-response curves for all subjects were linear across the concentration ranges tested. The Perosphere Technology PoC coagulometer detects a range of therapeutic levels of the DOACs apixaban, rivaroxaban, edoxaban, and dabigatran, as well as the low molecular weight heparin, enoxaparin, with high precision and sensitivity. Please check and confirm the processed affiliations are correct . and amend if necessary.

Scientific ReportsVol. 15(1)
Hofstra University (US)
Openalex Percentile: Top 93%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.