Low-cost composite autosampler for wastewater sampling

Wastewater monitoring is a proven method for detecting viruses, illicit drug consumption, pharmaceutical use/abuse, water pollution, and the occurrence of antimicrobial resistance genes. Analyzing sewage water for pathogens like the SARS-Cov-2 virus could enable early detection of infected areas or virus variants. We developed a low-cost (∼US$1000), open-source, composite automatic water sampler with operational flexibility and simple data logging. Sample quantity is measured and cut off appropriately by continuously weighing the incoming liquid. Our system is customizable in both its hardware and firmware (via options and code modification) which allows for the device to be tailored easily to each application. For example, the user can input sampling quantities from 10 g per sample every 1.5 min to a single 2900 g sample after up to a 16-day delay prior to sampling. The outer diameter and height of the sampler are less than 0.5 m to fit in human-entry openings<b>.</b> We present experimental data for sample sizes of 10 g and 100 g at suction heights between 0.65 and 4.75 m.

Authors

Institutions

Publication Details

Journal
HardwareX
Published
2025-03-01
DOI
https://doi.org/10.1016/j.ohx.2025.e00631
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-cost composite autosampler for wastewater sampling

Hadi A. Al-agele, Chet Udell, J. S. Selker, Cara Walter et al.
HardwareX
Biosensors and Analytical Detection
article

Low-cost composite autosampler for wastewater sampling

Hadi A. Al-agele, Chet Udell, J. S. Selker, Cara Walter, Bao D. Nguyen, Liam P Zimmermann, Gurpreet Singh
article en

Abstract

Wastewater monitoring is a proven method for detecting viruses, illicit drug consumption, pharmaceutical use/abuse, water pollution, and the occurrence of antimicrobial resistance genes. Analyzing sewage water for pathogens like the SARS-Cov-2 virus could enable early detection of infected areas or virus variants. We developed a low-cost (∼US$1000), open-source, composite automatic water sampler with operational flexibility and simple data logging. Sample quantity is measured and cut off appropriately by continuously weighing the incoming liquid. Our system is customizable in both its hardware and firmware (via options and code modification) which allows for the device to be tailored easily to each application. For example, the user can input sampling quantities from 10 g per sample every 1.5 min to a single 2900 g sample after up to a 16-day delay prior to sampling. The outer diameter and height of the sampler are less than 0.5 m to fit in human-entry openings<b>.</b> We present experimental data for sample sizes of 10 g and 100 g at suction heights between 0.65 and 4.75 m.

HardwareXVol. 21
Oregon State University (US), Ministry of Higher Education and Scientific Research (IQ)
National Science Foundation, National Institute of Food and Agriculture, Ohio State University Foundation
Clean water and sanitation
Openalex Percentile: Top 96%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Low-cost composite autosampler for wastewater sampling — Hadi A. Al-agele, Chet Udell, et al. · HardwareX (2025) | TGRS Research Map | TGRS