A novel microextraction method for further elemental impurity determination in oily pharmaceutical excipients by ICP-MS

In this study, a reversed-phase dispersive liquid-liquid microextraction (RP-DLLME) method was proposed for the subsequent determination of elemental impurities of class 1 (As, Cd, Hg, and Pb) and class 2 A (Co, Ni, and V) in oily pharmaceutical excipients, as recommended by the International Council for Harmonisation (ICH) guideline Q3D. Analyte determination was carried out by inductively coupled plasma mass spectrometry (ICP-MS). Operational parameters were evaluated, including dispersant and extractant solvents, total volume and proportion of the extraction solution, sample mass, temperature, heating time, centrifugation, and stirring. Suitable results were obtained using a high sample mass (5 g), 2 mL of 50:50% (v/v) of n -propanol:HNO 3 (3 mol L -1 HNO 3 for all analytes and 6 mol L -1 HCl only for Hg), heating at 85 °C for 20 min, stirring for 1 min, and centrifugation for 10 min. Accuracy was assessed using certified reference materials (CRMs) of mineral oil, comparison with a reference method (microwave-assisted wet digestion), and analyte recovery experiments at three concentration levels, following ICH Q3D recommendations and the United States Pharmacopeia (USP) guidelines for injectable drugs. No statistical differences were observed in any of the accuracy assessments. The method achieved low quantification limits (LOQs) of 0.045, 0.006, 0.006, 0.009, 0.040, 0.020, and 0.102 µg g -1 for As, Cd, Co, Hg, Ni, Pb, and V, respectively, all of which were below the maximum levels allowed by the ICH guideline. The proposed method presented several advantages for routine analysis, including simplicity, high throughput, the use of diluted solutions, and minimal laboratory waste generation.

Authors

Institutions

Publication Details

Journal
Journal of Pharmaceutical and Biomedical Analysis Open
Published
2025-03-01
DOI
https://doi.org/10.1016/j.jpbao.2025.100063
Citations
3
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
2.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel microextraction method for further elemental impurity determination in oily pharmaceutical excipients by ICP-MS

Mariele S. Nascimento, Cristian Rafael Andriolli, Rochele S. Picoloto, Alessandra S. Henn et al.
3 citations
Journal of Pharmaceutical and Biomedical Analysis Open
Analytical chemistry methods development
2.26
article

A novel microextraction method for further elemental impurity determination in oily pharmaceutical excipients by ICP-MS

Mariele S. Nascimento, Cristian Rafael Andriolli, Rochele S. Picoloto, Alessandra S. Henn, Érico M.M. Flores, Éder Lisandro Moraes Flores
article en
3 citations

Abstract

In this study, a reversed-phase dispersive liquid-liquid microextraction (RP-DLLME) method was proposed for the subsequent determination of elemental impurities of class 1 (As, Cd, Hg, and Pb) and class 2 A (Co, Ni, and V) in oily pharmaceutical excipients, as recommended by the International Council for Harmonisation (ICH) guideline Q3D. Analyte determination was carried out by inductively coupled plasma mass spectrometry (ICP-MS). Operational parameters were evaluated, including dispersant and extractant solvents, total volume and proportion of the extraction solution, sample mass, temperature, heating time, centrifugation, and stirring. Suitable results were obtained using a high sample mass (5 g), 2 mL of 50:50% (v/v) of n -propanol:HNO 3 (3 mol L -1 HNO 3 for all analytes and 6 mol L -1 HCl only for Hg), heating at 85 °C for 20 min, stirring for 1 min, and centrifugation for 10 min. Accuracy was assessed using certified reference materials (CRMs) of mineral oil, comparison with a reference method (microwave-assisted wet digestion), and analyte recovery experiments at three concentration levels, following ICH Q3D recommendations and the United States Pharmacopeia (USP) guidelines for injectable drugs. No statistical differences were observed in any of the accuracy assessments. The method achieved low quantification limits (LOQs) of 0.045, 0.006, 0.006, 0.009, 0.040, 0.020, and 0.102 µg g -1 for As, Cd, Co, Hg, Ni, Pb, and V, respectively, all of which were below the maximum levels allowed by the ICH guideline. The proposed method presented several advantages for routine analysis, including simplicity, high throughput, the use of diluted solutions, and minimal laboratory waste generation.

Journal of Pharmaceutical and Biomedical Analysis OpenVol. 5
Universidade Federal de Minas Gerais (BR), Universidade Tecnológica Federal do Paraná (BR), Universidade Federal de Santa Maria (BR)
Zero hunger
Openalex Percentile: Top 15%
Analytical chemistry methods development
2.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.