A design strategy for long-term stability of porous PEEK implants by regulation of porous structure and in vivo mechanical stimulation

The bioinert nature of polyether ether ketone (PEEK) material limits the widespread clinical application of PEEK implants. Although the porous structure is considered to improve osseointegration of PEEK implants, it is hardly used due to its mechanical properties. This study investigated the combined influence of the porous structure and in vivo mechanical stimulation on implantation safety and bone growth based on finite element analysis of the biomechanical behavior of the implantation system. The combined control of pore size and screw preloads allows the porous PEEK implant to achieve good osseointegration while maintaining a relatively high safety level. A pore size of 600 µm and a preload of 0.05 N·m are the optimal combination for the long-term stability of the implant, with which the safety factor of the implant is >2, and the predicted percentage of effective bone growth area of the bone-implant interface reaches 97%. For further clinical application, PEEK implants were fabricated with fused filament fabrication (FFF) three-dimensional (3D) printing, and clinical outcomes demonstrated better bone repair efficacy and long-term stability of porous PEEK implants compared to solid PEEK implants. Moreover, good osteointegration performance of 3D-printed porous PEEK implants was observed, with an average bone volume fraction >40% three months after implantation. In conclusion, 3D-printed porous PEEK implants have great potential for clinical application, with validated implantation safety and good osseointegration.

Authors

Institutions

Publication Details

Journal
Bio-Design and Manufacturing
Published
2025-03-01
DOI
https://doi.org/10.1631/bdm.2400259
Citations
7
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
4.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A design strategy for long-term stability of porous PEEK implants by regulation of porous structure and in vivo mechanical stimulation

Enchun Dong, Jibao Zheng, Changning Sun, Jianfeng Kang et al.
7 citations
Bio-Design and Manufacturing
Bone Tissue Engineering Materials
4.72
article

A design strategy for long-term stability of porous PEEK implants by regulation of porous structure and in vivo mechanical stimulation

Enchun Dong, Jibao Zheng, Changning Sun, Jianfeng Kang, Chaozong Liu, Chuncheng Yang, A Ruhan, Ling Wang, Jie Zhang, Shuguang Liu, Dichen Li, Yingjie Liu
article en
7 citations

Abstract

The bioinert nature of polyether ether ketone (PEEK) material limits the widespread clinical application of PEEK implants. Although the porous structure is considered to improve osseointegration of PEEK implants, it is hardly used due to its mechanical properties. This study investigated the combined influence of the porous structure and in vivo mechanical stimulation on implantation safety and bone growth based on finite element analysis of the biomechanical behavior of the implantation system. The combined control of pore size and screw preloads allows the porous PEEK implant to achieve good osseointegration while maintaining a relatively high safety level. A pore size of 600 µm and a preload of 0.05 N·m are the optimal combination for the long-term stability of the implant, with which the safety factor of the implant is >2, and the predicted percentage of effective bone growth area of the bone-implant interface reaches 97%. For further clinical application, PEEK implants were fabricated with fused filament fabrication (FFF) three-dimensional (3D) printing, and clinical outcomes demonstrated better bone repair efficacy and long-term stability of porous PEEK implants compared to solid PEEK implants. Moreover, good osteointegration performance of 3D-printed porous PEEK implants was observed, with an average bone volume fraction >40% three months after implantation. In conclusion, 3D-printed porous PEEK implants have great potential for clinical application, with validated implantation safety and good osseointegration.

Bio-Design and ManufacturingVol. 8(2)
Central South University (CN), Foshan University (CN), National Medical Products Administration (CN), Royal National Orthopaedic Hospital (GB), Guangdong Province Stomatological Hospital (CN), Shaanxi Coal Chemical Industry Technology Research Institute (CN), Xiangya Hospital Central South University (CN), University College London (GB), Southern Medical University (CN), Xi'an Jiaotong University (CN)
Openalex Percentile: Top 5%
Bone Tissue Engineering Materials
4.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.