Data on the use of the wearable cardioverter defibrillator (WCD) among patients after cardiac implantable electronic device explantation of 1- to 3-chamber implantable cardioverter defibrillator systems (ICD) are sparse. Accordingly, several guidelines give a different recommendation regarding WCD indication in this cohort. We aimed to study the baseline characteristics and outcome of patients treated with WCD after ICD explantation. The primary outcome is appropriate WCD shock. Within a multicenter registry 109 patients received a WCD to bridge the time after ICD-system explantation until reimplantation due to a persistent ICD-indication. The mean follow-up was 824 ± 773 days. In addition to ventricular tachyarrhythmias and/or WCD shocks during WCD wear time, also the rate of rehospitalization for ventricular tachyarrhythmias, atrial fibrillation, stroke and congestive heart failure after ICD-reimplantation was evaluated. Patients had a mean age of 65 ± 14 years, and were hospitalized for 21 ± 15 days. The index left ventricular ejection fraction (LVEF) was at baseline 35.7 ± 14.1% and 35.7 ± 14.2% at short-term follow-up. Mean wear time of the WCD was 61 ± 46 days after ICD-system explantation. During that time an appropriate WCD shock was documented in 7.3% of patients. Up to 80.6% of patients after ICD-system explantation were re-implanted. The rates of rehospitalization due to ventricular tachyarrhythmias, heart failure and atrial fibrillation were 7.3%, 6.8% and 4.1%, respectively. After ICD-reimplantation the rate of appropriate shocks was 12/89 (13.4%). Occurrence of malignant ventricular tachyarrythmia after ICD-system explantation is high and the use of WCD among these patients could be beneficial in preventing sudden cardiac death.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-03-01
DOI
https://doi.org/10.1038/s41598-025-91046-4
Citations
2
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
2.78
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable cardioverter defibrillator after ICD-system explantation: data from a multicenter registry

Christian Blockhaus, David Tenbrink, Mohammad Abumayyaleh, Boldizsar Kovacs et al.
2 citations
Scientific Reports
Cardiac pacing and defibrillation studies
2.78
article

Wearable cardioverter defibrillator after ICD-system explantation: data from a multicenter registry

Christian Blockhaus, David Tenbrink, Mohammad Abumayyaleh, Boldizsar Kovacs, Katharina Koepsel, Tobias C. Dreher, Ardan M. Saguner, Assem Aweimer, Mido Max Hijazi, İbrahim Akın, Hendrik Lapp, Andreas Mügge, Fırat Duru, Thomas Beiert, Julia W. Erath, Ibrahim El‐Battrawy, Thomas Kuntz, Dong‐In Shin, Norbert Klein
article en
2 citations

Abstract

Data on the use of the wearable cardioverter defibrillator (WCD) among patients after cardiac implantable electronic device explantation of 1- to 3-chamber implantable cardioverter defibrillator systems (ICD) are sparse. Accordingly, several guidelines give a different recommendation regarding WCD indication in this cohort. We aimed to study the baseline characteristics and outcome of patients treated with WCD after ICD explantation. The primary outcome is appropriate WCD shock. Within a multicenter registry 109 patients received a WCD to bridge the time after ICD-system explantation until reimplantation due to a persistent ICD-indication. The mean follow-up was 824 ± 773 days. In addition to ventricular tachyarrhythmias and/or WCD shocks during WCD wear time, also the rate of rehospitalization for ventricular tachyarrhythmias, atrial fibrillation, stroke and congestive heart failure after ICD-reimplantation was evaluated. Patients had a mean age of 65 ± 14 years, and were hospitalized for 21 ± 15 days. The index left ventricular ejection fraction (LVEF) was at baseline 35.7 ± 14.1% and 35.7 ± 14.2% at short-term follow-up. Mean wear time of the WCD was 61 ± 46 days after ICD-system explantation. During that time an appropriate WCD shock was documented in 7.3% of patients. Up to 80.6% of patients after ICD-system explantation were re-implanted. The rates of rehospitalization due to ventricular tachyarrhythmias, heart failure and atrial fibrillation were 7.3%, 6.8% and 4.1%, respectively. After ICD-reimplantation the rate of appropriate shocks was 12/89 (13.4%). Occurrence of malignant ventricular tachyarrythmia after ICD-system explantation is high and the use of WCD among these patients could be beneficial in preventing sudden cardiac death.

Scientific ReportsVol. 15(1)
Goethe University Frankfurt (DE), University of Bonn (DE), Witten/Herdecke University (DE), Heidelberg University (DE), University Hospital Bonn (DE), Klinikum St. Georg (DE), University Hospital Heidelberg (DE), University Hospital of Zurich (CH), Helios Klinikum Krefeld (DE), University Hospital Frankfurt (DE), St. Josef-Hospital (DE), University Medical Centre Mannheim (DE), University Hospital Carl Gustav Carus (DE), Technische Universität Dresden (DE), Ruhr University Bochum (DE)
Good health and well-being
Openalex Percentile: Top 11%
Cardiac pacing and defibrillation studies
2.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.