PPGAIHI: Efficient Authentication in Healthcare IoT via CNN- and Distance-Based Thresholding

With the proliferation of devices connected through the Internet of Things (IoT), the focus on biometric authentication (BA) has intensified, driven by the increasing demand for convenience and security. Photoplethysmography (PPG) signals are recognized for their high usability, emerging as a viable method for user identification and authentication in remote medical environments. This study introduces PPGAIHI, a PPG-based authentication in healthcare IoT designed for practical applications and utilizing 1-D convolutional neural networks for feature extraction. Thorough performance evaluations of both model- and distance-based recognition methods were conducted. Comparative analyses of various PPG-based techniques were performed across ideal and real-world conditions using three distinct datasets to assess the tradeoff between performance and learning/recognition time, leading to system configuration recommendations. In ideal conditions, model-based methods, such as the support vector machine (SVM) and shallow fully connected networks achieved perfect scores-similarly, all distance-based methods achieved a score of one, contingent upon the selected threshold. In practical scenarios, the SVM achieved optimal accuracy, reaching one with more than six segments during the recognition phase. Conversely, the distance-based Minkowski model achieved a superior accuracy of 0.9779 using 100 segments (160 s) for registration and 15 segments (24 s) for recognition. Furthermore, this investigation provides practical guidelines for selecting optimal thresholds in distance-based recognition tasks, significantly improving the feasibility of PPG-based BA systems in real-world applications. This research demonstrates significant advancements in developing adaptable and practical PPG-based BA systems, achieving high accuracy under both ideal and practical conditions while effectively balancing system performance and recognition time.

Authors

Institutions

Publication Details

Journal
IEEE Internet of Things Journal
Published
2025-02-28
DOI
https://doi.org/10.1109/jiot.2025.3546604
Citations
3
Primary Topic
Brain Tumor Detection and Classification
Type
article
Field-Weighted Citation Impact
2.53

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PPGAIHI: Efficient Authentication in Healthcare IoT via CNN- and Distance-Based Thresholding

In Cheol Jeong, Sunghan Lee, GyeongBong Kim
3 citations
IEEE Internet of Things Journal
Brain Tumor Detection and Classification
2.53
article

PPGAIHI: Efficient Authentication in Healthcare IoT via CNN- and Distance-Based Thresholding

In Cheol Jeong, Sunghan Lee, GyeongBong Kim
article en
3 citations

Abstract

With the proliferation of devices connected through the Internet of Things (IoT), the focus on biometric authentication (BA) has intensified, driven by the increasing demand for convenience and security. Photoplethysmography (PPG) signals are recognized for their high usability, emerging as a viable method for user identification and authentication in remote medical environments. This study introduces PPGAIHI, a PPG-based authentication in healthcare IoT designed for practical applications and utilizing 1-D convolutional neural networks for feature extraction. Thorough performance evaluations of both model- and distance-based recognition methods were conducted. Comparative analyses of various PPG-based techniques were performed across ideal and real-world conditions using three distinct datasets to assess the tradeoff between performance and learning/recognition time, leading to system configuration recommendations. In ideal conditions, model-based methods, such as the support vector machine (SVM) and shallow fully connected networks achieved perfect scores-similarly, all distance-based methods achieved a score of one, contingent upon the selected threshold. In practical scenarios, the SVM achieved optimal accuracy, reaching one with more than six segments during the recognition phase. Conversely, the distance-based Minkowski model achieved a superior accuracy of 0.9779 using 100 segments (160 s) for registration and 15 segments (24 s) for recognition. Furthermore, this investigation provides practical guidelines for selecting optimal thresholds in distance-based recognition tasks, significantly improving the feasibility of PPG-based BA systems in real-world applications. This research demonstrates significant advancements in developing adaptable and practical PPG-based BA systems, achieving high accuracy under both ideal and practical conditions while effectively balancing system performance and recognition time.

IEEE Internet of Things JournalVol. 12(12)
Hallym University (KR)
Ministry of Science and ICT, South Korea
Openalex Percentile: Top 12%
Brain Tumor Detection and Classification
2.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.